9.2. FAQ

Poor degree of drying
Purge air outlet is always
open ("fail-safe")
Purge air outlet constantly
closed (measuring gas flow
only)
Error signal upon switching
on unit
34
Temporary overload
Incorrect dimensioning
Aerosol ingress
Purge are flow blocked internally
Sensor is too old
Incorrect operating mode selected
Continuous overload
Fail-safe mode active
Incorrect installation direction
Software error
Sensor defective
Power failure (power LED off)
Power supply board defective
Unit overheating
Piston seal defect
Measuring gas jet is blocked
Incorrectly dimensioned unit
Sensor defective
Required performance parameters not yet
reached
PCB fault
Improve the operating conditions e.g.
increased operating pressure, prevent
sudden load changes
Implement larger dryer
Inspect filter element function and, where 
applicable, exchange it or introduce an
additional preliminary filter; inspect 
condensate drain-off function and replace it 
if necessary
Contact manufacturer: if necessary, return 
device for repair
Contact manufacturer: if necessary, return 
device for repair and/or exchange control
unit
Amend the operating mode
Improve operating conditions (e.g. increase
operating pressure); avoid sudden load
changes; check dryer dimensions; use larger
unit
Inspect error and fault messages: Flashing 
rhythm for LED indicates an error/fault; if 
necessary contact manufacturer
Inspect installation direction of device
Contact manufacturer: If necessary, return 
device for repair and/or replace control unit
Contact manufacturer: If necessary, return 
device for repair and/or replace control unit
Connect unit to power mains
Contact manufacturer: If necessary, return 
device for repair and/or replace control unit
The unit automatically resumes operation
when the internal temperature has dropped
<60°C
Contact manufacturer: If necessary, return 
device for repair and/or replace control unit
Contact manufacturer: If necessary, return 
device for repair and/or replace control unit
Use smaller dryer
Contact manufacturer: if necessary, return 
unit for repair or replace control unit
The moment the set performance range is
reached, the error message is automatically
reset (latest after 10 to 15 minutes)
→ otherwise, identify cause of the problem: 
the flashing rate and interval of the red 
LED indicate the type of the error/fault; if 
necessary, contact manufacturer
Contact manufacturer: if necessary, return 
unit for repair or replace control unit