TABLE 2. SUPPLY, FLOW RATES, WEIGHTS & FLOW & SERVICE CONNECTIONS
Model
REU-AM1220WD - Infinity 12
REU-AM1620WD - Infinity 16
REU-AM2024WD - Infinity 20
REU-AM2626WD - Infinity 26
REU-AM2626WDL - Infinity 26 Touch
REU-A1620WB - B16
REU-A2024WB - B20
REU-A2626WB - B26
TABLE 3. MAXIMUM DELIVERY TEMPERATURES
(a) Factory "Pre-Set" Maximum delivery temperature (°C)
(b) Can the Factory "Pre-Set" Maximum delivery temperature be changed by an authorised person?
Non - 50°C Compliant - Models
(a)
60
60
60
(b)
Yes
Yes
Yes
TABLE 4. OTHER ACCESSORIES
Contact Rinnai for more information about our accessory range and model suitability, or visit: www�rinnai�com�au�
SMART BOX (plastic)
RECESS BOX (metal)
PIPE COVER
SECURITY
CAGE
SECURITY
BRACKET
SIDEWAYS FLUE
DIVERTER
WATER
CONTROLLERS
Rinnai
Water Supply
Pressure
Min
Max
MJ/hr
kPa
92
120
1000
124
120
1000
156
160
1000
199
200
1000
199
200
1000
124
120
1000
156
160
1000
199
200
1000
60
60
60
60
Yes
Yes
Yes
Yes
Recess boxes are available in either plastic or metal, and are designed to permit a recessed
installation of a Rinnai Continuous Flow water heater into a wall cavity, saving precious
space� Recess boxes are also suitable for painting�
Pipe covers attach easily to a Rinnai Continuous Flow water heater and are designed to
conceal pipes and valves� Pipe covers may also be joined to one another to conceal longer
pipe work�
Protects the Rinnai Continuous Flow water heater from theft and damage�
Prevent theft of your Rinnai Continuous Flow water heater by securing it with the custom
security bracket�
Designed to redirect flue products when a Rinnai Continuous Flow water heater is installed
on a balcony�
An extended range of Deluxe Kitchen, Deluxe Bathroom and Wireless water controllers are
also available�
Max Flow at Temp Rise
(at minimum water supply pressure)
L/min / °C
15 / 20
12 / 25
7.5 / 40
20 / 20
16 / 25
10 / 40
24 / 20
20 / 25 12.5 / 40 10 / 50
26 / 20
26 / 25 16.3 / 40 13 / 50
26 / 20
26 / 25 16.3 / 40 13 / 50
20 / 20
16 / 25
10 / 40
24 / 20
20 / 25 12.5 / 40 10 / 50
26 / 20
26 / 25 16.3 / 40 13 / 50
60
50
50
Yes
No
No
27
SPECIFICATIONS
Fittings
Hot
kg
(DN = mm)
6 / 50
13.5 R ½ (15) R ½ (15) R ¾ (20)
8 / 50
13.5 R ½ (15) R ½ (15) R ¾ (20)
14.5 R ¾ (20) R ¾ (20) R ¾ (20)
15.5 R ¾ (20) R ¾ (20) R ¾ (20)
15.5 R ¾ (20) R ¾ (20) R ¾ (20)
8 / 50
13
R ½ (15) R ½ (15) R ¾ (20)
14
R ¾ (20) R ¾ (20) R ¾ (20)
15
R ¾ (20) R ¾ (20) R ¾ (20)
50°C Compliant - Models
50
50
50
50
No
No
No
No
Cold
Gas
50
50
No
No
HW_CF OIM