WATER TEMPERATURE CONTROL

UNIVERSAL WATER CONTROLLER (MC-601Q) OPERATION

PREHEAT INDICATOR
Indicates that the Smartstart preheater (when fitted) is
activated.
PREHEAT BUTTON
Used to start and stop the Smartstart preheat unit (when
fitted), See Smartstart Operation on page 11.
CONTROLLER PRIORITY INDICATOR
Indicates if this water controller is in control of water
delivery temperature.
PRIORITY TRANSFER BUTTON
Used to transfer control priority between water
controllers. The water controller with priority has
command of the hot water delivery temperature.

Turning On

If the water controller is switched off (No digits displayed in the digital monitor window)
press the On/Off button once� The ON indicator will illuminate, indicating that the hot
water unit will be ready to supply hot water once a hot water tap is opened�

Adjusting Temperature

Select the desired temperature using the Hot water temp
required temperature is displayed on the digital monitor.
To operate the hot water unit, open any hot water tap� This will automatically light the
burner providing hot water� The water heater 'In Use' indicator will illuminate on the
water controller(s).
Once the hot water is running, if the set temperature is either too hot or cold press the
Hot water temp
or
Whilst hot water outlets are open, the set temperature may be lowered to a minimum of 37°C� For
safety, it cannot then be raised above 43°C until all hot water taps are closed�
NOTE
If the water heater is turned 'Off' whilst hot water taps are open it can not be turned back 'On' until
all hot water taps have been closed�
Temperatures higher than 50ºC MUST NOT be able to be selected on controllers installed in
bathrooms, ensuites or toilets� This is to help reduce the risk of burns from hot water� If this is not
the case, the controllers have been incorrectly installed� CONTACT YOUR INSTALLER�
The 'beep' sound can be muted by pressing the
3 seconds� To cancel sound muting, simply repeat the process�
Always check outlet water temperature before use� The parent / carer MUST check the temperature
before placing dependants in contact with hot water, see "Warning About Hot Water" on page 4�
CAUTION

Transferring Priority

To control the water delivery temperatures when using two or more water controllers it is
necessary to have priority transferred to the water controller you wish to use� Transferring
of priority will NOT be possible if the 'In Use' indicator is currently illuminated, as this
indicates hot water is flowing and that another water controller already has priority.
An illuminated Priority indicator confirms that the desired water controller is in control
of the water delivery temperature� If the Priority indicator is not illuminated press the
Priority Transfer button once� The Priority indicator will illuminate, indicating that hot
water temperature control has been transferred and that the hot water unit will be ready
to supply hot water once a hot water tap is opened�
Water Controller Combinations & Configurations
Wireless, Universal and Deluxe water controllers can be combined, Refer to "Water Controller Combinations &
Configurations" on page 9 to confirm the maximum number and combination of controllers that can be fitted.
Rinnai
buttons until the desired temperature is reached�
Indicates that a water heater is delivering hot water.
Indicates the temperature selected.
Error messages flash in event of a fault.
TEMPERATURE CONTROL BUTTONS
Used to select water temperature.
Indicates that the hot water heater is on.
Used to switch the water heater on and off.
or
buttons until the
and
buttons simultaneously for more than
10
WATER HEATER 'IN USE' INDICATOR
DIGITAL MONITOR
WATER HEATER ON INDICATOR
ON/OFF BUTTON
ON!
ON!
COLD
COLD
HOT
HOT
HW_CF OIM