3.4.3. Bracket Mounting Procedure

1. Align the two mounting holes in the transmitter with the two slots in the mounting bracket
and assemble the (2) M8 hex cap screws, (2) lockwashers and (2) flat washers provided.
Rotate transmitter assembly to the desired position and torque the M8 hex cap screws to 27,0
Nm/20,0 Lb-ft maximum.
2. Pipe Mount Option: Refer to
or vertical pipe, and install a "U" bolt around the pipe and through the holes in the bracket.
Secure the bracket with the nuts, flat washers and lock washers provided.
3. Wall Mount Option: Position the bracket on the mounting surface at the desired location and
secure the bracket to the mounting surface using the appropriate hardware (Wall mounting
hardware requirements to be determined and supplied by the end user).
Figure 10 – Pipe Mounting Bracket Secured to a Horizontal or Vertical Flat Pipe and Angle pipe