Fujitsu WATERSTAGE 112 Maintenance Document page 68

Waterstage series 3 phase air/water heat pump split system, single service
Hide thumbs Also See for WATERSTAGE 112:
Table of Contents

Advertisement

Heat Pump, Split System, Single Service, 3 phase
COMMAND
ACCESS
LINE
LEVEL
7711
I
7720
I
7721
I
7722
I
7730
I
7820
I
7823
I
7824
I
7830
I
7831
I
7832
I
7833
I
7841
I
7846
I
7855
I
7914
I
7915
I
7916
I
8000
I
8001
I
8003
I
8004
I
8006
I
8011
I
8022
I
8050
I
8052
I
8054
I
8056
I
8058
I
8060
I
8062
I
8064
I
8066
I
8068
I
8402
I
8403
I
8406
I
8410
U
8411
U
8412
U
8413
U
8425
I
8454
S
8455
S
8456
S
8457
S
8700
U
8701
U
8702
U
8703
I
8704
I
68
FUNCTION
Voltage signal UX
Digital output test
Digital output DO1
Digital output DO2
Outside temp B9
Sensor temp BX1
Sensor temp BX4
Sensor temp BX5
Sensor temp BX21 module 1
Sensor temp BX22 module 1
Sensor temp BX21 module 2
Sensor temp BX22 module 2
Contact state H1
Contact state H2
Contact state H3
Input Ex4
Input Ex5
Input Ex6
State of plant
State heating circuit 1
State heating circuit 2
State DHW
State cooling circuit 1
State heat pump
State swimming pool
State supplementary source
History 1
History 2
History 3
History 4
History 5
History 6
History 7
History 8
History 9
History 10
Diagnostics heat source
El imm heater 1 flow
El imm heater 2 flow
Condenser pump
Return temp HP
Setpoint HP
Flow temp HP
Compressor modulation
Temp diff condenser
Locking time HP
Counter number of locks HP
Hours run el flow
Start counter el flow
Diagnostics consumers
Outside temperature
Outside temp min
Outside temp max
Outside temp attenuated
Outside temperature composite
SETTING RANGE
0...10volt
0 volt
No test
All OFF
No test
Digital output DO1
Digital output DO2
Cooling mode
Heating mode
Heating mode
On/off
Off
-50...50°C
0°C
-28...350°C
0°C
-28...350°C
0°C
-28...350°C
0°C
-28...350°C
0°C
-28...350°C
0°C
-28...350°C
0°C
-28...350°C
0°C
Open/closed
Open
Open/closed
Open
Open/closed
Open
0/230V
0
0/230V
0
0/230V
0
0
0
0
0
0
0
0
Date/time/code
Date/time/code
Date/time/code
Date/time/code
Date/time/code
Date/time/code
Date/time/code
Date/time/code
Date/time/code
Date/time/code
Off/on
Off
Off/on
Off
Off/on
Off
0...140°C
0°C
0...140°C
0°C
0...140°C
0°C
0...100%
0%
-50...140°C
0°C
0...2730h
00:00:00
0...65535
0
0...2730h
00:00:00
0...65535
0
-50...50°C
0°C
-50...50°C
50°C
-50...50°C
-50°C
-50...50°C
0°C
-50...50°C
0°C
Maintenance Document 1394-1