Fujitsu WATERSTAGE 112 Maintenance Document page 128

Waterstage series 3 phase air/water heat pump split system, single service
Hide thumbs Also See for WATERSTAGE 112:
Table of Contents

Advertisement

Heat Pump, Split System, Single Service, 3 phase
Connection:
The room thermostat must be connected to one of
the terminals b (CL+, CL-) of the heat pump controller
board. To do this, you can use a 0.5mm² cable of the
two-pair telephone cable type.
6
5
If
the
installation
is
thermostats,
the
second
connected to the second terminal block b.
Configuration:
Gain access to the settings by continuously pressing the "Heating mode" key
fs = 1 (factory setting)
fs = 2
fs = 3
P1 = 1 (factory setting) Automatic save:
Correction of the setpoint using the knob is accepted without special confirmation (timeout) or by pressing the
operating mode key.
P1 = 2 Confirm save
Correction of the setpoint with the knob is accepted only after pressing the operating mode key.
128
4
3
2
1
equipped
with
2
thermostat
must
If the cable is shielded, the shielding can be
connected to the controller CL- terminal. It may under
no circumstances be connected on both sides, i.e.
controller side and room unit side.
1 CL+
2 CL-
room
be
The room unit is addressed as ZONE 1
The room unit is addressed as ZONE 2
The room unit is addressed as ZONE 3 (factory setting)
User interface
Maintenance Document 1394-1