Biasi RIVA COMBI Service Manual page 52

Wall hung gas boiler for central heating and domestic hot water supply
Table of Contents

Advertisement

___________________________________________________________________________________________________
Third Part (edition-0106) Ignition and Detection Electrodes, Burner and Injectors
_______________________________________________________________
6) Remove the burner moving it to the left,
rotating it upward and then pulling it outside
the combustion chamber (follow the arrows
on Figure 5).
2
1
RIVA COMBI SERVICE MANUAL – REV A
C
Figure 4
3
Figure 5
7) Unscrew the screws D (Figure 6) which hold
the electrodes to the burner.
D
8) Extract the electrodes from the burner.
9) Re-assemble the parts carrying out the
removal operation in reverse order.
Note: The metallic edge of the detection
electrode is longer than the one of the
ignition electrodes.
Figure 6
14-2