Code
Function
035
ServeRAID
075
Power supply
Result
Aborted
Test setup error: No ServeRAID adapter found on
system board or PCI bus
Failed
Adapter in slot n; adapter/drive configuration error
(where n is the slot number of the failing adapter)
Adapter in slot n; internal error
(where n is the slot number of the failing adapter)
Logical drive m on adapter in slot n
(where m is the number of the failing logical drive and
n is the slot number of the adapter)
On system board; internal error
On system board; adapter/drive configuration error
Logical drive on system board adapter
Adapter in slot n; memory allocation error
(where n is the slot number of the failing adapter)
On system board; memory allocation error
On system board; PCI configuration error
On system board; POST error
Adapter in slot n; POST error
(where n is the slot number of the failing adapter)
Adapter in slot n; PCI configuration error
(where n is the slot number of the failing adapter)
SCSI drive on adapter in slot n, SCSI ID m
(where n is the slot number of the adapter and m is
the SCSI ID of the drive)
Failed
Voltage sensed by the system is out of range
Description
Action
Make sure that the
ServeRAID adapter is
properly installed. If the
problem remains,
replace the ServeRAID
adapter. If the problem
persists, call for service.
1. Run the ServeRAID
Configuration Utility.
2. If the problem
remains, replace the
ServeRAID adapter
in slot n.
If the problem persists,
call for service.
Run the ServeRAID
Configuration Utility.
If the problem persists,
call for service.
Call for service.
Replace the ServeRAID
adapter in slot n. If the
problem persists, call for
service.
Check the cable and
power connections on
the drive. If the problem
persists, call for service.
Call for service.