Advertisement

Quick Links

ENGLISH
IT-20
INSTRUCTION MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for JUKI IT-20

  • Page 1 ENGLISH IT-20 INSTRUCTION MANUAL...
  • Page 2: Table Of Contents

    CONTENTS 1. INTROdUCTION ..................1 2. CONNECTING THE COUNT MANUAL SwITCH ........1 3. USB pORT ....................1 4. CONfIGURATION ..................2 5. BASIC OpERATION pROCEdURE ............3 5-1. Normal startup mode .......................... 3 (1) Normal startup mode screen ......................4 (2) No.
  • Page 3: Introduction

    • Some type of the USB device may not be properly recognized by this sewing machine. • JUKI does not compensate for loss of data stored on the USB device caused by using it with this sewing machine. 2 USB specifications •...
  • Page 4: Configuration

    4. CONfIGURATION D E F Switch/indication description Clock LED Lights up when the clock is displayed. 7-segment indication block Indicates various ID data and clock information. Lights up when Product No. ID is displayed on Product No. LED → See “5-1.
  • Page 5: Basic Operation Procedure

    5. BASIC OpERATION pROCEdURE 5-1. Normal startup mode When the power supply is turned on, the item screen and ID data which had been selected before it was turned off in the previous operation. The selected item and the number for which the ID is registered are indicated in LED.
  • Page 6: Normal Startup Mode Screen

    (1) Normal startup mode screen ■ product No. display screen Press the switch is pressed. After 3 seconds The 16-digit Product No. ID is indicated. A registered ID can be set up from the No. switch. Press the switch is pressed.   ...
  • Page 7: No. Switch Input Procedure Under Normal Startup Mode

    ID is indicated successively from the first 4 digits. If the Id is 1234 5678 9ABC dEfG, it is indicated as follows and the indication switches to the clock when the entire Id is indicated. After 1.5 seconds After 1.5 seconds Clock indication After 3 seconds After 1.5 seconds...
  • Page 8: List Of No. Input Patterns By Switches

    (3) List of No. input patterns by switches indication: Lights up.   indication: Blinks. First switch Second switch First switch Second input input input switch input After 1 second After 1 second After 1 second After 1 second After 1 second when No.30 (switches ) is input, Id will be unselected.
  • Page 9: Outputting Measurement Data

    (4) Outputting measurement data When switch is pressed for one second or longer under normal mode, USB data writing function is enabled. When switch is pressed for one second or longer, network data transmission function is enabled. “Wait” blinks on the 7-segment indication block during data output.
  • Page 10: Setup Mode

    5-2. Setup mode (1) Setup mode screen When the power supply is turned on with switch pressed, the system starts up in setup mode. In setup mode, the setting item Press the switch. is selected by using MAC address check screen ■...
  • Page 11: Mac Address Check Screen

    (2) MAC address check screen Since MAC address is set up for each device, it can only be checked on the IT panel. Press the switch 3 to switch the block indication for MAC address. – 9 –...
  • Page 12: Memory Switch Setup Screen

    (3) Memory switch setup screen Panel operation can be varied by changing the memory switch setting. Press the switch on the memory switch setup screen and display the memory switch No. The memory switch can be selected by pressing switch switch in this condition.
  • Page 13 ■ Memory Switch data List description Initial value Network offline setting Network connection validity/invalidity is selected. OFF : Network connection is enabled. ON : Network connection is prohibited. Clock correction function Clock correction validity/invalidity when there is network connection is set up. OFF : Clock correction is not enabled.
  • Page 14: Clock Setup Screen

    (4) Clock setup screen The year, month, date, hour, minute and second are set up on the clock setup screen. Press switch 1 or switch 2 to enter the date and time. Then, confirm the entry by pressing switch 3 . ■...
  • Page 15: Initialization Screen

    (5) Initialization screen Panel data is initialized on the initialization screen. Press the switch on initialization screen and indicate the initialization No. The initialization No. can be selected by pressing the switch switch in this condition. 0 : Initialization is not executed. 1 : Memory switch and so forth are initialized.
  • Page 16: Usb Format Screen

    (6) USB format screen The external medium connected at the USB is formatted on the USB format screen. “YES” is displayed when the switch is pressed on the USB format screen. “YES” and “NO” are switched by pressing the switch switch Press the switch...
  • Page 17: Ip Address Setup Screen

    (7) Ip address setup screen The method to obtain the IP address is selected on the IP address setup screen. Ip address mode selection ■ Select the method by pressing the switch switch with the IP address mode selected, and confirm the selection by pressing the switch When DHCP or APIPA is selected as the method, the...
  • Page 18: Version Check Screen

    Manual selection of Ip address ■ When manual input is selected, the IP address input screen will appear. Select the IP address using the switch switch for each block and then confirm with the switch * The screen will blink during setup. …...
  • Page 19: Software Rewrite Mode

    5-3. Software rewrite mode When the power supply is turned ON with switch pressed, the system will start up in IT-20 application soft- ware rewrite mode. Load the software and press the switch while “PGWr” is displayed to start software rewrite.
  • Page 20: Error Indication

    6. ERROR INdICATION This system enables interlock (or restriction of functions) to prevent the problem from spreading in case a problem is detected, and contains the following error codes to notify the problems. When requesting for service, please also check the error code. Error code display Error code Error description...

Table of Contents