Test Mode - Furuno Felcom15 Operator's Manual

Ship security alert system (ssas)
Hide thumbs Also See for Felcom15:
Table of Contents

Advertisement

FELCOM 16 (by PC)
1. Press the [F7] key to display the Options menu.
2. Press the [7] key ([6] key when the FELCOM functions as an EGC receiver) to display
the Test menu.
3. Press the [4] key.
4. Press the [Enter] key to start the test.
INF: Distress/SSAS Buttons entered into TEST MODE.
The display shows the message (in red) "SSAS buttons are under test. Cancel the test
mode if a real SSAS alert needs to sent." appears.
5. Open the button cover on the No. 1 SSAS.
6. Push the button in (ON). The CAUTION window displays the message "SSAS UNIT
works correctly." appears if the unit is functioning properly.
7. 30 seconds after the button is pushed in the SSAS test report is automatically sent to the
station(s) whose Mode set on the SSAS Report window is "Real+Test" or Real Only".
8. Turn the button of the No. 1 SSAS off (
Note: To test the No. 2 and No. 3 SSAS repeat steps 6-8.
1. PV Test
2. PV Test Result
3. Diagnostic Test
4. SSAS Button Test
Options
Test
1. Login
SSAS Button Test
2. Logout
1. PV Test
3. Abort
2. PV Test Result
4. Select NCS
3. Self Test
5. Ocean Region
4. Distress Alarm Button Test
6. Test
Options
Test
1. Login
Distress/SSAS Button Test
2. Logout
1. PV Test
3. Abort
2. PV Test Result
4. Select NCS
3. Self Test
Distress/SSAS buttons are under test mode.
CAUTION
5. Ocean Region
4. Distress Alarm Button Test
Press any key to escape.
6. Test
<Press ESC key to continue>

Test mode

Test
Start
Yes
No
).
24