Furuno FELCOM16 Installation Manual
Furuno FELCOM16 Installation Manual

Furuno FELCOM16 Installation Manual

Inmarsat mini-c mobile earth station ship security alarm system (ssas)
Hide thumbs Also See for FELCOM16:

Advertisement

Quick Links

INMARSAT MINI-C MOBILE EARTH STATION
FELCOM16
PRINTED IN JAPAN

Advertisement

Table of Contents
loading

Summary of Contents for Furuno FELCOM16

  • Page 1 INMARSAT MINI-C MOBILE EARTH STATION FELCOM16 PRINTED IN JAPAN...
  • Page 2: Safety Instructions

    SAFETY INSTRUCTIONS CAUTION WARNING Do not open the equipment Confirm that the power supply voltage unless totally familiar with is compatible with the voltage rating electrical circuits and of the equipment. service manual. Connection to the wrong power supply Only qualified personnel can cause fire or equipment damage.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS EQUIPMENT LISTS ..................... iii SYSTEM CONFIGURATION................iv 1. MOUNTING THE UNIT ..................1 1.1 Antenna Unit........................1 1.2 Communication Unit ......................7 1.3 AC/DC Power Supply Unit PR-240-CE (option) ...............7 2. WIRING ......................8 2.1 Antenna Cable Connector at the Terminal Unit ..............9 3.
  • Page 4: Equipment Lists

    EQUIPMENT LISTS Standard Supply Name Type Code No. Remarks Antenna Unit IC-116 Communication Unit IC-216 Junction Box* IC-315 w/CP16-02501 SSAS Alert Unit* IC-307 w/CP16-03101, FP16-00901 CP16-02101 004-439-060 For 15/30 m antenna cable** 1 set CP16-02111 004-439-070 For 50 m antenna cable** CP16-02121 004-439-080 For 100 m antenna cable**...
  • Page 5: System Configuration

    POWER SUPPLY 100/115/220/230 VAC AC-DC PRINTER 1φ, 50/60 Hz Power Supply PR-240-CE POWER SUPPLY PERSONAL 12-24 VDC FURUNO INMARSAT MINI-C MOBILE EARTH STATION COMPUTER POWER (PC/AT compatible) COMMUNICATION UNIT IC-216 (with internal GPS receiver) : Standard JUNCTION BOX IC-315 : Option...
  • Page 6: Mounting The Unit

    1. MOUNTING THE UNIT Antenna Unit Mounting Location • Mount the omnidirectional antenna unit high atop a mast clear of stays and the turning diameter of a radar antenna. The ideal mounting location would be where no obstacle appears in the fore and aft directions down to -5º and down to -15º in the port and starboard directions.
  • Page 7 1. MOUNTING THE UNIT • The allowable vibration level as specified by Inmarsat is as shown in the table below. Allowable vibration level Frequency Level 2 to 10 Hz 2.54 mm Peak Amplitude 10 to 100 Hz 9.8 m/s² Peak Acceleration •...
  • Page 8 1. MOUNTING THE UNIT For 15 or 30 m cable 1. Apply silicone sealant (local supply) to the threads of the pipe. 2. Unscrew three screws to remove the antenna base from the antenna unit. 3. Pass the antenna cable through the pipe, antenna base in order. 4.
  • Page 9 1. MOUNTING THE UNIT 10. Wrap self-bonding tape around the connection of antenna base and pipe, and then wind vinyl tape over self-bonding tape. 11. Remount the antenna unit (upper) on the antenna base. (Torque: 2.6 N·m ± 10%) 12. Fix the ground wire RW-4747 (supplied) between the ground terminal on the antenna unit and the ship’s ground point.
  • Page 10 1. MOUNTING THE UNIT For 50 or 100 m cable 1. Apply silicone sealant (local supply) to the threads of the pipe. 2. Unscrew three screws to remove the antenna base from the antenna unit. 3. Pass the cable assy TPA5FB0.3NJ5FBA-5DFB (supplied, 300 mm) through the shrink tube (supplied).
  • Page 11 1. MOUNTING THE UNIT 12. Fix the ground wire RW-4747 (supplied) between the ground terminal on the antenna unit and the ground stud on the mast. 13. Connect the antenna cable (50 or 100 m) and cable assy (attached at step 4). 14.
  • Page 12: Communication Unit

    1. MOUNTING THE UNIT Communication Unit Mounting Select the following place to mount the communication unit. • Provide sufficient ventilation. • For maintenance and checking purpose, leave sufficient space at the sides and rear of the unit. Use two tapping screws (4x40, supplied) to fix the communication unit. You can insert screws from the top and bottom side of the communication unit for bulkhead mounting.
  • Page 13: Wiring

    WIRING For 50 or 100m antenna cable 0.34 m CAUTION Cable assy Ground wire TPA5FB0.3NJ5FBA-5DFB RW-4747 0.3 m This unit is shipped with 10 A fuse. Replace fuse with 5 A when using TP58A15W-RG58, 15 m 8D-FB-CV, 50 m TP5FBAW-5DFBB, 30 m the equipment with the power supply 12D-SFA-CV, 100 m 24 VDC .
  • Page 14: Antenna Cable Connector At The Terminal Unit

    2. WIRING Antenna Cable Connector at the Terminal Unit 8D-FB-CV (50 m) Outer Sheath Dimensions in millimeters. Shield Remove outer sheath and armor by the Armor Inner Sheath dimensions shown left. Expose inner sheath and shield by the dimensions shown left. Cover with heat-shrink tubing and heat.
  • Page 15 2. WIRING 12D-SFA-CV (100) Dimensions in millimeters. Outer Sheath Armor Shield Inner Sheath Remove outer sheath and armor by the dimensions shown left. Expose inner sheath and shield by the dimensions shown left. Twist shield end. Slip on clamp nut, gasket and clamp as shown left. Clamp Gasket Washer...
  • Page 16: Settings After The Installation

    3. SETTINGS AFTER THE INSTALLATION Installing software After installing the equipment, install the FELCOM 16 software (F16PC) in the PC as follows: 1. Turn on the PC. 2. Set FD-ROM in floppy disk drive. 3. Click the icon of “SETUP.EXE” in the floppy disk. The setup procedure begins, showing the welcome dialog box.
  • Page 17: Changing Ship's Mains Specifications

    3. SETTINGS AFTER THE INSTALLATION 4. Click the [Next] button. Choose destination location dialog box 5. Click the [Next] button. Select program folder dialog box...
  • Page 18 3. SETTINGS AFTER THE INSTALLATION 6. Click the [Next] button. Start copying files dialog box 7. Click the [Next] button and the installation begins. When the installation is completed, the FELCOM 16 dialog box appears. FELCOM 16 dialog box...
  • Page 19 3. SETTINGS AFTER THE INSTALLATION 8. Click the Close button ( )at the top right corner of the dialog box. The “Setup Complete” dialog box appears. Setup complete dialog box Note: If you want to launch the program file now check the box next to “Yes, Launch the program file.”...
  • Page 20: Setting The Imn (Inmarsat Mobile No.)

    3. SETTINGS AFTER THE INSTALLATION Setting the IMN (Inmarsat Mobile No.) Set your IMN (Inmarsat Mobile No.) using the and PC as below. 1. Power on the communication unit and PC in order. 2. Double click [F16PC] on the screen to start the program. 3.
  • Page 21: Specifications

    CHANGING POWER SUPPLY SPECIFICATIONS The power supply PR-240-CE (option) is shipped with 220 VAC (200-230 VAC) setting. If the power supplys are 100 VAC – 115 VAC, change the tap connection and terminal connection as follows. Terminal board Power supply Tap connection Power supply label connection #1 &...
  • Page 23 A - 2 16AK-X-9405 CODE NO. CODE NO. CODE NO. CODE NO. TYPE TYPE TYPE TYPE IC-116 工事材料表 工事材料表 工事材料表 工事材料表 INSTALLATION MATERIALS 数量 番 号 名  称 型名/規格 略  図 用途/備考 Q'TY OUTLINE NAME DESCRIPTIONS REMARKS ケーブル組品 選択         12D-SFA-CV *100M* TO BE SELECTED CABLE ASSY.
  • Page 24 A - 3 004-439-060 16AK-X-9401 CODE NO. CODE NO. CODE NO. CODE NO. TYPE TYPE TYPE TYPE CP16-02101 工事材料表 工事材料表 工事材料表 工事材料表 INSTALLATION MATERIALS 番 号 名  称 型名/規格 数量 略  図 用途/備考 Q'TY OUTLINE NAME DESCRIPTIONS REMARKS イラックススリーブ SCM2 07-1220 クロ *40MM* SHRINK TUBING CODE NO.
  • Page 25 A - 4 004-439-070 16AK-X-9402 CODE NO. CODE NO. CODE NO. CODE NO. TYPE TYPE CP16-02111 TYPE TYPE 工事材料表 工事材料表 工事材料表 工事材料表 INSTALLATION MATERIALS 数量 番 号 名  称 型名/規格 略  図 用途/備考 Q'TY OUTLINE NAME DESCRIPTIONS REMARKS イラックススリーブ SCM2 07-1220 クロ *40MM* SHRINK TUBING CODE NO.
  • Page 26 A - 5 004-439-080 16AK-X-9403 CODE NO. CODE NO. CODE NO. CODE NO. TYPE TYPE CP16-02121 TYPE TYPE 工事材料表 工事材料表 工事材料表 工事材料表 INSTALLATION MATERIALS 数量 番 号 名  称 略  図 型名/規格 用途/備考 Q'TY NAME OUTLINE DESCRIPTIONS REMARKS イラックススリーブ SCM2 07-1220 クロ *40MM* SHRINK TUBING CODE NO.
  • Page 27: Packing Lists

    PACKING LIST 24AA-X-9852 -6 PR-240-CE N A M E DESCRIPTION/CODE № O U T L I N E Q'TY ユニット UNIT PR-240-CE AC-DC電源 POWER SUPPLY UNIT 000-053-879 工事材料 INSTALLATION MATERIALS CP24-00151 PR-240-CE電源変更手順書 C52-00205-A POWER MODIFICATION PROCEDURES 000-147-013 24-003-4101-3 デンゲンハリマーク POWER LABEL 100-299-773 +トラスタッピンネジ...
  • Page 28 D - 1 Jan. 7, '03...
  • Page 32 *00080934702* *00080934702* *00080934702* *00080934702* ( ( HIMA HIMA ) ) FELCOM16 FELCOM16 * 0 0 0 8 0 9 3 4 7 0 2 * * 0 0 0 8 0 9 3 4 7 0 2 * *IME56380C00* *IME56380C00*...

Table of Contents