  • Page 1 Back SHIP SECURITY ALERT SYSTEM (SSAS) (For FELCOM12/15/16)
  • Page 2 The paper used in this manual is elemental chlorine free. FURUNO Authorized Distributor/Dealer FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, 9-52 Ashihara-cho, Nishinomiya 662-8580, JAPAN Nishinomiya 662-8580, JAPAN Telephone : Telephone : 0798-65-2111 0798-65-2111 0798-65-4200 0798-65-4200 FIRST EDITION : FIRST EDITION : MAY.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS SYSTEM CONFIGURATION ..................2 1. OVERVIEW OF SSAS ....................4 2. INSTALLATION......................6 2.1 Mounting ......................... 6 2.1.1 Junction box (for FELCOM 16) ................6 2.1.2 I/F box IC-312 (for FELCOM 12)................7 2.1.3 SSAS alert unit ....................... 8 2.2 Wiring..........................10 2.2.1 Junction box (for FELCOM 16) ................
  • Page 4: System Configuration

    100-115/200-230 VAC PRINTER Power Supply 1φ, 50/60 Hz COMMUNICATION UNIT IC-216 PR-240-CE 24 VDC (with internal GPS receiver) PERSONAL FURUNO INMARSAT MINI-C MOBILE EARTH STATION COMPUTER 12-24 VDC POWER (PC/AT compatible) : Standard JUNCTION BOX SSAS Alert Unit SSAS Alert Unit...
  • Page 5 FELCOM 12 Antenna Unit IC-112 Navigator 100/110/200/220V 1φ, 50/60 Hz Communication Distress Alert Unit AC-DC Unit IC-302 Power Supply IC-212 PR-300 INMARSAT-C MOBILE EARTH STATION 24 VDC Received Call Unit POWER IC-303 Distress Alert Unit Terminal Unit IC-302 IB-581/IB-582 24 VDC Distress Message Controller 24 VDC DMC-5...
  • Page 6: Overview Of Ssas

    1. OVERVIEW OF SSAS The IC-307 SSAS (Ship Security Alert System) Alert Unit connects to the Inmarsat-C MES FELCOM 15/FELCOM 12 or the Inmarsat Mini-C FELCOM 16 for the purpose of alerting specified addresses (for example, your ship’s company) that your ship is under attack by intruders.
  • Page 7 SSAS operation flow Open the cover of the button and then press the button. (This is a latch-type button; hit and release to activate the button.) ↓ If addresses have been preset, the SSAS report is sent to one address 30 seconds after the button is activated. (Max.
  • Page 8: Installation

    2. INSTALLATION 2.1 Mounting 2.1.1 Junction box (for FELCOM 16) The junction box IC-315 is required when installing the SSAS on the FELCOM 16; it is already installed on the FELCOM 15. Separate the junction box from a magnetic compass by the distances shown below to prevent deviation to a magnetic compass.
  • Page 9: I/F Box Ic-312 (For Felcom 12)

    2.1.2 I/F box IC-312 (for FELCOM 12) The I/F box is required to connect the SSAS alert unit to the FELCOM 12. The I/F box is connected to the communication unit with a 5 m cable (17JE-573-10 harness). Accordingly, locate the interface within 5 m of the communication unit. Keep the following compass safe distances in mind when choosing the mounting location: Standard compass: 0.65 m Steering compass: 0.45 m...
  • Page 10: Ssas Alert Unit

    2.1.3 SSAS alert unit Separate the junction box from the SSAS alert unit by the distances shown below to prevent deviation to a magnetic compass. Standard compass: 0.70 m Steering compass: 0.45 m Locate the SSAS alert unit where it cannot be found by intruders. The location should be known only by ship’s captain and authorized personnel.
  • Page 11 5. Attach the switch cover as shown below. Note that the cover may be turned 180° to change cover opening direction. Press here and hold down for five seconds. Switch cover Flush mounting The optional flush mount kit OP16-28 (Code No. 004-448-010) is required. Name Type Code No.
  • Page 12: Wiring

    2.2 Wiring 2.2.1 Junction box (for FELCOM 16) Use the junction box IC-315 to connect the SSAS alert unit to the FELCOM 16. Unfasten four screws to remove the cover to connect cables to terminal board. For detailed wiring information see the interconnection diagram. For connection, use the JIS cable TTYCS-4 (or equivalent, see next page for sectional view of this cable) or the CO-SPEVV-SB-C 0.2x5P.
  • Page 13: I/F Box Ic-312 (For Felcom 12)

    2.2.2 I/F box IC-312 (for FELCOM 12) FELCOM 12 is connected to the SSAS Alert Unit via the I/F Box IC-312. For detailed wiring refer to the interconnection diagram at the back of this manual. Communication Unit (rear view) BUZZER DMC1 DMC2 BREAKER...
  • Page 14: Ssas Alert Unit

    2.2.3 SSAS alert unit Three SSAS alert units can be connected. For wiring, see the illustrations below and the interconnection diagram at the back of this manual. For the terminal unit (FELCOM 15) and the communication unit (FELCOM 16/FELCOM 12), the wiring of the SSAS is monitored and if in error “TROUBLE: SSAS UNIT connection abnormality.”...
  • Page 15: Initial Settings

    3. Type “furunoservice” (without quotation marks) in the Enter JOB No. field and then press the [Enter] key. The prompt PASSWORD appears. 4. Enter password (see FURUNO Information for SSAS) then press the [Enter] key. Then, the item Main Menu is displayed in reverse video.
  • Page 16: Operation

    3. OPERATION 3.1 Operation Mode There are two menu operating modes: Menus other than SSAS-related menus are displayed. Normal mode: SSAS manager mode: The mode is activated by the password entered by the ship’s captain or authorized personnel. The indication “SSAS Manager Mode”...
  • Page 17: Ssas Manager Mode

    3.1.2 SSAS manager mode All SSAS-related settings are set in the SSAS manager mode. Do the following to access this mode. 1. FELCOM 15/FELCOM 12: Press [F8], [F2] to show the System Setup menu. FELCOM 16: Press [F8], [F1] to show the System Setup menu. 2.
  • Page 18: Setting Ssas Report Destination And Message Contents

    3.2 Setting SSAS Report Destination and Message Contents When the SSAS is activated, the SSAS report is sent according to the addresses (max. 5) and message content set with SSAS Report 1 – SSAS Report 5 on the SSAS Report menu. Note 1: The destination and message content of an SSAS report varies according to Administration.
  • Page 19 4. FELCOM 15/16: Press the [↓] key to choose Mode and then press the [Enter] key. FELCOM 12: Go to step 6. Real+Test Real Only Test Only 5. Press the [↑] or [↓] key to choose mode desired and then press the [Enter] key. “Mode”...
  • Page 20 14. Press the [6] key to display the SSAS Message Contents menu. SSAS Message Contents _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Vessel Name : _ _ _ _ _ _ _ _ _ MMSI...
  • Page 21: Transmitting Ssas Report

    3.3 Transmitting SSAS Report In the normal mode, the SSAS report is sent 30 seconds after the button on the SSAS is pressed. The SSAS repeatedly transmits the report even if the button is pushed off ( ). Repeated transmission can only be stopped from the SSAS manager mode. 1.
  • Page 22 Note 1: You may cancel repeated transmission from either operating mode by pushing the button OFF→ON→OFF→ON→OFF. You must allow no more than three seconds to elapse before pushing the button again. If more than three seconds elapses, repeat the procedure. When transmission is stopped, the message “INF: SSAS UNIT activation has been cancelled.”...
  • Page 23: Testing The Button

    3.4 Testing the Button The SSAS button can be tested as below. Note 1: An actual SSAS report cannot be transmitted during the testing. Note 2: The equipment must be in the SSAS manager mode to conduct the test. FELCOM 15 1.
  • Page 24 9. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is stopped and the message shown below appears to notify you that normal operation has been restored. CAUTION INF: Distress/SSAS Buttons returned to NORMAL OPERATION. <Press ESC key to continue>...
  • Page 25 FELCOM 16 (no PC) Turn off communication unit. Turn on button of No. 1 SSAS. Turn on communication unit. 30 s POWER, LOGIN and TX lamps flash in that order. Send SSAS No (within 30 s) test report? Yes (after 30 s) SSAS report is sent to station(s) whose mode is "Real+Test"...
  • Page 26: Test Mode

    FELCOM 16 (by PC) 1. Press the [F7] key to display the Options menu. 2. Press the [7] key ([6] key when the FELCOM functions as an EGC receiver) to display the Test menu. Test 1. PV Test 2. PV Test Result 3.
  • Page 27 9. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is stopped and the message shown below appears to notify you that normal operation has been restored. CAUTION INF: SSAS Buttons returned to NORMAL OPERATION. <Press ESC key to continue>...
  • Page 28 Options Test 1. Login Distress/SSAS Button Test 2. Logout 1. PV Test 3. Abort 2. PV Test Result 4. Select NCS 3. Self Test Distress/SSAS alert button test mode. CAUTION 5. Ocean Region Press any key to escape. 4. Distress Alarm Button Test INF: DMC/SSAS switch TEST started.
  • Page 29: Ssas Report Test

    3.5 SSAS Report Test You can test for successful transmission of the SSAS report to the address you specify, without using the button. The test report message states “!!! Test Call !!!” to alert the receiver of the message that it is a test call. Note: This function is only available in the SSAS manager mode.
  • Page 30 Mar.03'05...
  • Page 31 Y. Hatai...
  • Page 32 Y. Hatai...
  • Page 34: Interconnection Diagrams

    *4. GROUND THRU CONNECTOR CLAMP. *5. USER SUPPLY. SCALE MASS NAME INMARSAT-C MES *6. TB BOARD (16P0116) REQUIRED. CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5 *7. CHANGE SETTING OF JUMPER IN IC-307 FOR TERMINATOR. CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5 DWG No. INTERCONNECTION DIAGRAM C5635-C01- J FURUNO ELECTRIC CO., LTD.
  • Page 36 *6. 2 OR 3 SETS CAN BE CONNECTED. MASS SCALE NAME INMARSAT-C MES 終端のIC-307はジャンパー設定の変更が必要。 CHANGE JUMPER SETTING IN LAST IC-307. CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5 *7)コネクタの取り替えが必要。 *7. REPLACE CONNECTOR. CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5 DWG No. INTERCONNECTION DIAGRAM C5613-C01- J FURUNO ELECTRIC CO., LTD.