Vco Attenuation 12.5 Khz; Vco Attenuation 20 Khz - Motorola PR400 Basic Service Manual

Commercial series
Hide thumbs Also See for PR400:
Table of Contents

Advertisement

Radio Alignment Procedures: Transmitter Alignment Options
spin control can also be toggled via its up/down arrow buttons. The softpot value can also be
typed into the edit control (press ENTER to confirm your selection/send a softpot value).
3. Inject 1 kHz at an appropriate level until 2.3 V rms is measured at the AC/DC METER (radio
input) if using test box RLN4460.
4. Record the deviation obtained.
5. Adjust the slider; adjust the spin control or key in softpot values (press ENTER to confirm) for the
frequency point until the deviation is within the range specified in
6. Dekey the radio (Press the PTT Toggle button). Choose the next frequency, key up and repeat
steps 3 to 6 until all seven tuning points are done.
7. Program the softpot value by pressing the Program button.
8. Exit the VCO Attn. 25 kHz function.

5.4.4.2 VCO Attenuation 12.5 kHz

Note:
Tuning of Modulation Balance Attenutation and VCO Attenuation for 25 kHz channel
bandwidth must be done first.
1. Under the Tx Align menu, select VCO Attenuation 12.5 kHz.
2. Press PTT Toggle to key up the radio at the last non-0 transmit frequency point (normally F7).
3. Inject 1 kHz at an appropriate level until 2.3 V rms is measured at the AC/DC METER (radio
input) if using test box RLN4460.
4. Record the deviation obtained.
5. Adjust the slider, adjust the spin control or key in softpot values (press ENTER to confirm) for the
frequency point until the deviation is within the range specified in
6. Press PTT Toggle to dekey the radio.
7. Program the softpot value by pressing the Program button.
8. Exit the VCO Attenuation 12.5 kHz function.

5.4.4.3 VCO Attenuation 20 kHz

Note: Tuning of Modulation Balance Attn. and VCO Attn. for 25 kHz channel bandwidth
must be done first.
1. Under the Tx Align menu, select VCO Attenuation 20 kHz.
2. Press PTT Toggle to key up the radio at the last non-0 transmit frequency point (normally F7).
3. Inject 1 kHz: at an appropriate level until 2.3V rms is measured at the AC/DC METER (radio
input) if using test box RLN4460.
4. Record the deviation obtained.
5. Adjust the slider; adjust the spin control or key in softpot values (press ENTER to confirm) for the
frequency point until the deviation is within the range specified in
6. Press PTT Toggle to dekey the radio.
7. Program the softpot value by pressing the Program button.
8. Exit the VCO Attn. 20 kHz function.
6881096C24-A
Table
5-4.
Table
5-4.
Table
5-4.
July, 2004
5-9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents