NOTE: When using STP cable in bundles or conduits, consider the following:
•
Do not exceed 40% fill capacity in conduits.
•
Do not comb the cable for the first 20 m, where cables are straightened, aligned,
and secured in tight bundles.
•
Loosely place cables and limit the use of tie wraps or hook-and-loop fasteners.
•
Separate twisted pair cables from AC power cables.
Twisted Pair Cable Termination for Pass-Through Ethernet Communication
The twisted pair cable used for Ethernet communication depends on the network speed.
The LAN connectors support both 10BASE-T (10 Mbps Ethernet) and 100BASE-T
(100 Mbps Fast Ethernet), half-duplex and full-duplex Ethernet connections. Terminate
the RJ-45 connectors for Ethernet communcation with straight-through or crossover
termination standards.
NOTES:
•
Do not use standard telephone cables. Telephone cables do not support Ethernet
or Fast Ethernet.
•
To avoid transmission errors, do not stretch or bend the cables.
Crossover cable — Wire one end of the twisted pair cable with the T568A standard
•
and the other with the T568B standard. Use this to connect to a computer.
Straight-through (patch) cable — Wire both ends of the twisted pair cable with the
•
T568B standard. Use this to connect to a switch, hub, or router.
Straight-Through Cable
Pin End 1 Wire
1
White-orange White-orange
2
Orange
3
White-green
4
Blue
5
White-blue
6
Green
7
White-brown
8
Brown
Figure 8.
End 2 Wire
Orange
White-green
Blue
White-blue
Green
White-brown
Brown
RJ-45 Pin Assignment
Crossover Cable
Pin End 1 Wire
End 2 Wire
1
White-green
White-orange
2
Green
Orange
3
White-orange White-green
4
Blue
Blue
5
White-blue
White-blue
6
Orange
Green
7
White-brown
White-brown
8
Brown
brown
XTP T USW 103 4K Switcher • Installation
Pins:
1 2 3 4 5 6 7 8
Side View
Insert Twisted
Pair Wires
RJ-45 Connector
12