Advertisement

BA01290G/00/EN/03.16
71329708
Valid as of software version:
3.1.0 and 4.0.0
Products

Operating Instructions

Tankvision
Multi Scan NXA83B
Installation manual
Solutions
Services

Advertisement

Table of Contents
loading

Summary of Contents for Endress+Hauser NXA83B

  • Page 1: Operating Instructions

    Products Solutions Services BA01290G/00/EN/03.16 71329708 Valid as of software version: 3.1.0 and 4.0.0 Operating Instructions Tankvision Multi Scan NXA83B Installation manual...
  • Page 2 Tankvision Multi Scan NXA83B Order code 00X00-XXXX0XX0XXX Ser. No.: X000X000000 TAG No.: XXX000 Serial number www.endress.com/deviceviewer Endress+Hauser Operations App A0023555 Endress+Hauser...
  • Page 3: Table Of Contents

    Tankvision Multi Scan NXA83B Table of Contents Document information ....4 Target audience for this manual ....4 Version history .
  • Page 4: Document Information

    Tankvision Multi Scan NXA83B Document information Target audience for this manual This manual should support during the installation of the NXA83B units. It deals with the mechanical, electrical and signal line installation. The first commisioning steps are described as well.
  • Page 5: Documentation

    Tankvision Multi Scan NXA83B Document information Result of a sequence of actions A0018373 Symbols in graphics Symbol Meaning 1, 2, 3 ... Item numbers ... Series of steps A, B, C ... Views Hazardous area Indicates a hazardous area. A0011187...
  • Page 6: Basic Safety Instructions

    IT security measures in line with operators' security standards and designed to provide additional protection for the device and device data transfer must be implemented by the operators themselves. Endress+Hauser can be contacted to provide support in performing this task. Designated use 2.3.1...
  • Page 7: Workplace Safety

    The device complies with the applicable standards and regulations as listed in the EC declaration of conformity and thus complies with the statutory requirements of the EG directives. Endress+Hauser confirms the successful testing of the device by affixing to it the CE mark.
  • Page 8: Introduction

    RS232, RS485, BPM, Current Loop etc. • An Ethernet port and two USB ports are also provided. • The NXA83B is available with a 7 in Widescreen LCD screen built into the front of the device, with navigation via a touch screen.
  • Page 9: Device Support And Compatibility

    Tankvision Multi Scan NXA83B Introduction NXA83_RackMount_Title 19 in Rack Mount Device Support and Compatibility The Multi Scan NXA83B is designed to interface to the following gauge and transmitter types: Supplier Gauge/transmitter type • NMR81 and NMR84 Micropilot • NRF81 Tankside Monitor Endress+Hauser •...
  • Page 10: Typical Connections

    Introduction Tankvision Multi Scan NXA83B Typical Connections NXA83_Typical-Connections SAAB TRL2 Ethernet (OPC) ENRAF BPM DCS (MODBUS) MODBUS Tank Gauges ENRAF CIU 858 WHESSOE 550 VAREC MARK/SPACE Endress+Hauser...
  • Page 11: Installation

    Installation Installation Mechanical Installation The Multi Scan NXA83B is available in two different enclosures - Wall Mount or 19 in Rack Mount. All versions of the Multi Scan NXA83B are intended for installation within a building and should not be mounted in hazardous areas.
  • Page 12: Electrical Installation

    0.8 A 40 W The Multi Scan NXA83B contains a 20 × 5 mm (0.79 × 0.2 in) cartridge fuse protecting the mains input. The fuse is rated at 3.15 A, time delay (antisurge/slow blow). The fuse must be...
  • Page 13: Network And Usb Connections

    Scan NXA83B, such as flash memory ‘sticks’, printers and modems. They are compliant with the USB 2.0 specification. Serial Ports The Multi Scan NXA83B has eight serial ports available for connection to gauges or host computers. These are: • COM 1 – COM 8 The serial ports will use the RS232 hardware specification by default.
  • Page 14: Led Module

    LED Module The Multi Scan NXA83B has an LED module which consists of a bank of eight pairs of LEDs, one pair for each of the serial ports, to indicate communication activity. One LED is transmit and the other one is receive.
  • Page 15 Tankvision Multi Scan NXA83B Installation Interface connection Pins Relay contacts 1 – 6 Relay 1 contacts 2 – 7 Relay 2 contacts 3 – 8 Relay 3 contacts 4 – 9 Relay 4 contacts NXA83_Interface-Connection_Internal-Relay-Board Each contact pair may be configured to be N/O or N/C.
  • Page 16 Installation Tankvision Multi Scan NXA83B Interface connection Pins SAAB TRL2 SCREEN NXA83_Interface-Connection_Enraf-BPM 4.6.6 Whessoe Current Loop Connection Connector Type: Phoenix Connector, Screw Terminal Interface connection Pins WHESSOE 20 mA LOOP + SCREEN LOOP – NXA83_Interface-Connection_Enraf-BPM 4.6.7 HART Connection Connector Type: Phoenix Connector, Screw Terminal...
  • Page 17 Tankvision Multi Scan NXA83B Installation 4.6.10 V1 Connection Connector Type: Phoenix Connector, Screw Terminal Interface connection Pins HART FIELDBUS 0 V SCREEN FIELDBUS +24 V NXA83_Interface-Connection_Enraf-BPM Endress+Hauser...
  • Page 18: Index

    Tankvision Multi Scan NXA83B Index Designated use........6 Electrical Installation.
  • Page 19 Tankvision Multi Scan NXA83B Endress+Hauser...
  • Page 20 71329708 www.addresses.endress.com...