Oscilloscope
The MANUALplus 620 features an integrated oscilloscope. Both
X/t and X/Y graphs are possible. The following characteristic curves
can be recorded and stored in six channels:
•
Actual value and nominal value of the axis feed rate
•
Contouring feed rate
•
Nominal and actual position
•
Following error of the position controller
•
Content of PLC operands
•
Encoder signal (0° – A) and (90° – B)
•
Difference between position and speed encoder
•
Nominal velocity value
•
Integral-action component of the nominal current value
•
Torque-determining nominal current value
Logic signals
Simultaneous graphic representation of the logic states of up to 16
operands (markers, words, inputs, outputs, counters, timers)
•
Marker
•
Input
•
Output
•
Timers
•
Counter
•
IpoLogik
TNCscope
PC software for transferring the oscilloscope files to a PC.
With TNCscope you can record and save up to 16 channels
(accessory)
simultaneously.
API DATA
The API DATA function enables the control to display the states
or contents of the symbolic API markers and API double words.
This function requires that your PLC program use the symbolic
memory interface.
Note: The API DATA function does not provide usable display
values with the iTNC 530-compatible memory interface (API 1.0).
Table function
The current conditions of the markers, words, inputs, outputs,
counters and timers are displayed in tables. The conditions can be
changed through the keyboard.
Trace function
The current content of the operands and the accumulators is
shown in the statement list in each line in hexadecimal or decimal
code. The active lines of the statement list are marked.
Log
For the purposes of error diagnostics, all error messages and
keystrokes are recorded in a log. The entries can be read using the
PLCdesign or TNCremo software for PCs.
TeleService
PC software for remote diagnostics, remote monitoring and
remote operation of the control. For more information, please ask
(accessory)
for the Remote Diagnosis with TeleService Technical Information
sheet.
In Diagnosis mode, the structure of the HSCI/PROFIBUS system
Bus diagnosis
as well as the details of the HSCI/PROFIBUS components can be
displayed in a clearly laid out screen. For HSCI components this is
possible even to the level of individual terminals.
(M)
(I)
(O)
(T)
(C)
(X)
57