DEC MicroVAX 3100 85 Troubleshooting Instructions page 27

Table of Contents

Advertisement

Example 1-4 represents a case where one SIMM of a set is missing or incorrectly
installed. In this case, only one set of SIMMs was installed. Since one was
missing, there is no usable memory for testing to run
to
completion. SIMM ID is
missing here.
Example 1-4 No_Memory_Present Test Failure
KA55-A or KA51-A V2.3, VMB 2.14
Performing normal system tests.
74 .. 73 .. 72 .. 71..70 .. 69 .. 68 .. 67 .. 66 .. 65 .. 64 .. 63 .. 62 .. 61. .60 ..
?
Test Subtest DC 87 Loop Subtest=OO Err Type=FF
DE NO Memory present.lis
Vec=OOOO Prev-Errs=OOOO -P1=EF42EF42
P2=00000000
P3=OOOOOOOO P4=00000000
P5=00000000 P6=7F337F7F
P7=00000000
P8=0000EF42
P9=00000001 P10=2006B8D8
rO=00000002
r1=21018000
r2=00000008
r3=00000007
r4=03FFFFEO
r5=80000000
r6=FFFFFFFF r7=00000000
r8=00000000
r9=20140758
r10=FFFFFFFE r11=FFFFFFFF
dser=OOOO cesr=OOOOOOOO intmsk=OO icsr=Ol pcsts=FAOO pcadr=FFFFFFF8 pcctl=FC13
cctl=00000020 bcetsts=0360 bcedsts=OFOO cefsts=00019200 nests=OO
mmcdsr=00666640 mesr=OOOOOOOO
Error:
SIMM Set 0 (OA,OB,OC,OD)
SIMM OA = 16MB
SIMM OB = 16MB
SIMM OC = 16MB
Total of OMB, 0 good pages, 0 bad pages, 0 reserved pages
Normal operation not possible.
SIMM OD = OOMB
??
Troubleshooting and Diagnosing Problems 1-21