Example 1-3 represents a case where one SIMM of a set was bad. In this
example, SIMM 1G was bad or incorrectly installed.
Example 1-3 Memory_Count_Pages Test Failure
KA55-A or KA51-A V2.3, VMB 2.14
Performing normal system tests.
74 .. 73 .. 72 .. 71. . 70 .. 69 .. 68 .. 67 .. 66 .. 65 .. 64 .. 63 .. 62 .. 61. .60 .. 59 ..
58 .. 57 .. 56 .. 55 .. 54 .. 53 .. 52 .. 51. .50 .. 49 .. 48 .. 47 .. 46 .. 45 .. 44 .. 43 ..
42 .. 41. . 40 .. 39 .. 38 .. 37 .. 36 .. 35 .. 34 .. 33 .. 32 ..
? Test_Subtest 40 06 Loop_Subtest=OO Err_Type=FF
DE_Memory_count_pages.lis
31. .30 .. 29 .. 28 .. 27 .. 26 .. 25 .. 24 .. 23 .. 22 .. 21. .20 .. 19 .. 18 .. 1 7 .. 16 ..
15 .. 14 .. 13 .. 12 .. 11. .10 .. 09 .. 08 .. 07 .. 06 .. 05 .. 04 .. 03 ..
16 MB RAM, SIMM Set (OA,OB,OC,OD) present
Memory Set 0: 04000000 to 04FFFFFF, 16MB, 32768 good pages, 0 bad pages
Error:
SIMM Set 1 (lE,lF,lG,lH)
SIMM IE = 64MB
SIMM IF = 64MB
SIMM IG = 64MB??
SIMM IH
=
64MB
Memory Set
1:
00000000 to-03FFFFFF, 64MB, 0 good pages, 131072 bad pages
Total of 80MB, 32768 good pages, 131072 bad pages, 136 reserved pages
Tests completed.
1-20 Troubleshooting and Diagnosing Problems