You can use test 9E with the test number as a parameter to show a list of
legal parameters and valid values for the test number. For example, enter T
9E 30 to show a list of legal parameters and valid values for test number 30
(Memory _In it_Bitmap).
There is a dependency between some tests.
Failures can occur if dependencies between tests are not followed.
Any parameter not entered is given a default value. Enter T 9E nn, where
nn is test number to show defaults. During power-up testing or execution of
any script of tests (AO to BF), the values of parameters are determined by the
script, not defaults.
You may dump the contents of a script by entering T 9E nn, where nn is a
script to dump. Scripts are always in range of AO to BF (or 0 for the power-up
script).
You must enter three zeros (0) as place holders for the three parameters that
occur before the user-specified parameter, mark_hard_SBEs. The last value (1)
is a parameter. You can then specify the mark_hard_SBEs parameter in the
Memory_Init_Bitmap test as follows:
»> T 30 0 0 0 1
The resulting messages differ, depending on the function of the test or utility.
However, most failing tests cause the system to display error messages similar to
the following:
»> T SF 1
? Test Subtest 5F 18 Loop Subtest=OE Err Type=FF
DE SGEC.lis
Vec=OlOC Prev-Errs=OOOO -Pl=OOOOOOOI
P2=00000000
P3=827DFF03 P4=00000000
P5=00000000 P6=00000000
P7=00000000
P8=00000001
P9=00000000 PIO=OOOOOOOO
rO=00000054
rl=000082E2
r2=00000001
r3=000082FA
r4=00008230
r5=00000040
r6=000082E2
r7=20008000
r8=00008000
r9=20140758
r10=13000001 r11=2014044B
EPC=2005721A dser=OOOO cesr=OOOOOOOO icsr=Ol pcsts=F800 pcctl=FC13
cctl=00000007 bcetsts=03AO bcedsts=0400 cefsts=00019200 nests=OO
mmcdsr=00C6C600 mesr=00006000
»>
Write down the error messages before you contact your Digital services
representative.
Troubleshooting and Diagnosing Problems 1-17