Log Set Placement; Thermostat Installation - Quadra-Fire PELLET INSERT CB1200I Owner's Manual

Pellet insert installation and operation
Hide thumbs Also See for PELLET INSERT CB1200I:
Table of Contents

Advertisement

R
R R
I. Optional Log Set Placement Instructions
CAUTION
Logs are FRAGILE. Use extreme care when handling or
cleaning logs.
1.
Place the front log in first as shown in Figure 25.1
charred area surrounding firepot.
2.
Set the left and right logs onto the front log, placing
the holes in the base of the left and right logs over the
locating pins in the front log. See Figure 25.2. Ensure
that the charred ends are facing the firepot.
LOCATING PINS
Figure 25.1
Charred Areas in the Back
Top Log, Left
Figure 25.2
NOTE:
Due to the abrasive nature of a pellet appliance fire, the
logs are not covered under warranty. Any placement vari-
ation other than shown here can cause excessive heat
and shall void the appliance warranty.
February 3, 2010
Top Log
Right
Front Log
J. Thermostat Installation
A 12 volt AC thermostat is required to operate this pellet
1
.
appliance. You may use the included wall mount thermo-
stat or purchase an optional programmable thermostat
or remote control. The included thermostat is equipped
with an adjustable heat anticipator. The current rating is
.05 amps. The anticipator needs to be adjusted to the
lowest setting available.
2.
When mounting a thermostat on a wall, be sure to follow
your thermostat installation instructions carefully.
NOTE: Thermostat must be mounted level for accu-
rate readings. The thermostat should be mounted on
an inside wall and not in direct line with the appliance
convection air. Remove any packaging from inside
the thermostat before using.
NOTE: If the thermostat is located too close to the
appliance, you may need to set the temperature
setting slightly higher to maintain the desired tem-
perature in your home.
3.
Open right side plane to access a 4 screw terminal block
located on the bottom right hand side next to the power
cord inlet. The center 2 screws are for the thermostat
wires. The outer 2 are the mounting screws for the ter-
minal block. Figure 25.3.
Shock hazard.
• Do NOT remove grounding prong from plug.
• Plug directly into properly grounded 3 prong
receptacle.
• Route cord away from appliance.
• Do NOT route cord under or in front of appli-
ance.
Figure 25.3
7014-188B
CB1200-I Pellet Insert
CAUTION
Terminal Block
Center 2 Screws for
Thermostat Wires
Power Outlet
Page 25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cb1200mi-mbk

Table of Contents