Replace The Datatrak Module Battery Or Fuse - Graco N22DT0 Instructions-Parts List Manual

Nxt air motor
Hide thumbs Also See for N22DT0:
Table of Contents

Advertisement

DataTrak Operation
Replace the DataTrak Module
Battery or Fuse
To reduce the risk of fire and explosion, the battery
and fuse must be replaced in a non-hazardous loca-
tion.
Use only an approved replacement battery, shown in
Table 2, and an approved fuse, shown in Table 3.
Use of an unapproved battery or fuse will void
Graco's warranty and Intertek and Ex approvals.
1. Remove two screws (135). Carefully slide the Data-
Trak module (131) out of the housing (132). See
F
. 4.
IG
Series
Letter
F
. 4. Remove DataTrak Module
IG
2. Disconnect the runaway solenoid and sensor cables
from the module board. See F
3. Take the DataTrak module (131) to a non-hazard-
ous location.
14
132
131
135
TI8216c
. 5.
IG
4. To replace the battery, disconnect the used bat-
tery and replace with an approved battery.
Use only a Graco-approved replacement fuse (131a).
Table 2: Approved Batteries
Energizer alkaline # 522
Varta alkaline # 4922
Ultralife lithium # U9VL
Duracell alkaline # MN1604
5. To replace the fuse (131a):
a. Remove the screw, metal strap, and plastic
holder.
b. Pull the fuse away from the board.
c. Replace with a new fuse (131a).
Table 3: Approved Fuses
Series*
A
B and later
* F
. 4 shows where to find the Series letter.
IG
Sensor Cable Connection
Fuse (131a)
Solenoid Cable Connection
F
. 5. DataTrak Battery and Fuse Location
IG
Fuse Required
NXT413
24V216
Battery
TI7757a
311238ZAM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents