Replace The Datatrak Module Battery Or Fuse - Graco NXT Instructions Manual

Air motor
Table of Contents

Advertisement

DataTrak Operation
Replace the DataTrak Module
Battery or Fuse
The battery and fuse must be replaced in a non-haz-
ardous location.
1. Remove two screws (135). Carefully slide the
DataTrak module (131) out of the housing (132).
See F
. 4.
IG
F
. 4. Remove DataTrak Module
IG
2. Disconnect the runaway solenoid and sensor cables
from the module board. See F
3. Take the DataTrak module (131) to a non-hazardous
location.
Use only the following approved replacement batter-
ies. Use of an unapproved battery will void Graco's
warranty and FM and Ex approvals.
Ultralife lithium # U9VL
Duracell alkaline # MN1604
Energizer alkaline # 522
Varta alkaline # 4922
4. To replace the battery, disconnect the used battery
and replace with an approved battery.
12
132
131
135
TI8216b
. 5.
IG
Use only a Graco-approved replacement fuse (131a).
5. To replace the fuse (131a):
a. Remove the screw, metal strap, and plastic
holder.
b. Pull the fuse away from the board.
c. Replace with a new fuse (131a).
Sensor Cable
Connection
Fuse (131a)
Solenoid Cable
Connection
F
. 5. DataTrak Battery and Fuse Location
IG
Battery
TI7757a
311238G

Advertisement

Table of Contents
loading