Remote Datatrak Connection Kit Nxt406 - Graco N22DT0 Instructions-Parts List Manual

Nxt air motor
Hide thumbs Also See for N22DT0:
Table of Contents

Advertisement

Remote DataTrak Connection
Kit NXT406
1. Stop the pump during the upstroke. Follow the
Pressure Relief Procedure, page 20.
2. Disconnect the air line to the motor.
3. Pry off the top cover. Remove the air valve cover
and discard.
4. Install the reed switch sensor (139) and secure with
the screw (124) and o-ring (144). See F
nect the reed switch sensor cable (R) to the remote
DataTrak wire harness (76).
5. Route the wires to the top of the air valve. Install the
wire strain relief (74) with screw (45) and washer
(75) onto the reed switch sensor about 2 in. (50 mm)
behind the connection (C).
6. Route the remote DataTrak wire harness (76) down
the front of the air valve and carefully slide the
grommet (G) into the slot (S) of the new air valve
cover (47). There should be about 3 in. (76 mm) of
wire extending out of the air valve cover.
7. Install the new air valve cover (47) with the screw
(45), positioning the wire harness (76) so it will not
be pinched.
8. Reinstall the top cover (A).
9. Reconnect the air line to the motor.
10. Plug the cable from the remote DataTrak module
into the wire harness (76).
See your system operation manuals for complete
remote DataTrak instructions.
311238ZAM
. 17. Con-
IG
F
. 17. Remote DataTrak Connection Kit
IG
A
45
75
74
C
76
R
124
144
139
G S
Repair
45
47
TI10949A
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents