Necessary parts
(for 3W+N+PE, 230/400V) Certified power cable, minimum 4 mm² or AWG 10, 500V rated, cable diameter between 11 mm and
21 mm or
(for 3W+PE, 208V) Certified power cable, minimum 4 mm² or AWG 10, 300V rated, cable diameter between 11 mm and 21 mm
Circuit breaker maximum 40A

How to connect

1. Remove the back cover.
2. Remove the power input cover.
3. Loosen the cable gland fixation ring (1).
Note: The cable gland (1) is specified for cables with a diameter between 11mm and 21mm.
Image 4-12
Power cable connection
4. Push the stripped power supply cable through the cable gland. When using a flexible power cord, make sure that each conductor
end is provided with an end sleeve.
Fix the cable in the cable gland by securing ring 1 with an adjustable wrench.
5. Connect the power cord with the terminal barrier strip. Use a flat torque screw driver set to 1.4 Nm.
Always connect the ground wire (PE) with the connector indicated with PE on the terminal barrier strip.
If a neutral conductor is available, connect always to the connector indicated with N on the terminal barrier strip
Warning:
Always connect first the PE wire.
3W + PE
Image 4-13
Terminal connections
6. Reinstall the power connection cover.