Venting Systems; Full Reline With Outside Air - Horizontal; Illustrations Reflect Typical Installations And Are For Design Purposes Only; Actual Installation May Vary Due To Individual Design Preference - Quadra-Fire MTVERNINSAE-MBK Installation Manual

Hide thumbs Also See for MTVERNINSAE-MBK:
Table of Contents

Advertisement

MT VERNON AE INSERT
5

Venting Systems

A. Full Reline With Outside Air - Horizontal
CAUTION
Never draw outside combustion air from:
Wall, floor or ceiling cavity
Enclosed space such as an attic or garage
Figure 16.1
NOTE:
In Canada, where passage through a wall or partition of com-
bustible construction is desired, the installation shall conform
to CAN/CSA-B365.
16
NOTE; Use metal plate around
exhaust vent pipe and seal all
edges with non-flammable insu-
lation such as fiberglass, mineral
wool or ceramic.
Do not use high temperature
caulking materials to seal any
edge to prevent furture service-
ability.
Fire Risk.
Inspection of Chimney:
• Masonry chimney must be in good condition.
• Meets minimum standard of NFPA 211
• Factory-built chimney must be a minimum 6 inch
(152mm) UL103 HT.
Outside Air through Rear
Wall (Horizontal)
NOTE:
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation may vary due to individual design
preference.
7036-188J
WARNING
October 3, 2017