Analog Controls - Kaya Instruments JetCam19 User Manual

High speed camera jetcam series
Table of Contents

Advertisement

12.4 Analog controls

The GeniCam interface for this feature is described below:
Name
AnalogControl
GainSelector
Gain [GainSelector]
AnalogGain
BlackLevelSelector
BlackLevel
[BlackLevelSelector]
BlackLevelAuto
High Speed Camera User Guide
�� = ( �� + �������������������� ) ∗ ��������
Interface
Icategory
DigitalAll
DigitalRed
IEnumeration
DigitalGreen
DigitalBlue
IFLoat
1
2
IEnumeration
4
8
DigitalAll
DigitalRed
DigitalGreen
DigitalBlue
AnalogAll
IFloat
-1024 to 1024
Off
DigitalOnce
IEnumeration
DigitalContinuous
AnalogOnce
AnalogContinuous
Table 19 : Analog controls GeniCam names
Camera ISP specification
Values
Selects digital gain to control
Specifies the gain. The gain
written to register is
GainAll*GainX, where X is the
color
Analog gain.
Selects black level to control
Controls the DC offset applied
to each channel. The value
written to register will be
All+Color.
If selected AnalogAll the
control is done with VOFF +
VOFF invert bit in SSI
Description
45

Advertisement

Table of Contents
loading

Related Products for Kaya Instruments JetCam19

This manual is also suitable for:

Jetcam25Jetcam160Ky-jetcam

Table of Contents