Rated Indoor Airflow (Cfm) - Carrier 50TC Series Installation Instruction

Single package rooftop cooling only with puron (r-410a) refrigerant sizes 08, 12, and 14 with novation coil sizes 08 - 14 with round tube/plate fin coil
Hide thumbs Also See for 50TC Series:
Table of Contents

Advertisement

Rated Indoor Airflow (cfm)

The table to the right lists the rated indoor airflow used
for the AHRI efficiency rating for the units covered in this
document.
Position:
Example:
Unit Heat Type
50 - Electric Heat
Packaged Rooftop
Model Series - WeatherMaker
TC - Standard Efficiency
Heat Options
- = No Heat
Refrig. Systems Options
A = Standard One Stage Cooling Models
(sizes 08-12)
D = Two Stage Cooling Models
E = Two Stage Cooling Models with Al/Cu
Condenser Coils and Humidi-MiZer
Cooling Tons
08 = 7.5 tons
09 = 8.5 tons
12 = 10 tons
14 = 12.5 tons
Sensor Options
A = None
B = RA Smoke Detector
C = SA Smoke Detector
D = RA + SA Smoke Detector
E = CO
2
F = RA Smoke Detector and CO
G = SA Smoke Detector and CO
H = RA + SA Smoke Detector and CO
Indoor Fan Options
1 = Standard Static Option
2 = Medium Static Option
3 = High Static Option
Coil Options – RTPF (Outdoor - Indoor - Hail Guard)
A = Al/Cu - Al/Cu
B = Precoat Al/Cu - Al/Cu
C = E-coat Al/Cu - Al/Cu
D = E-coat Al/Cu - E-coat Al/Cu
E = Cu/Cu - Al/Cu
F = Cu/Cu - Cu/Cu
M = Al/Cu -Al/Cu — Louvered Hail Guard
N = Precoat Al/Cu - Al/Cu — Louvered Hail Guard
P = E-coat Al/Cu - Al/Cu — Louvered Hail Guard
Q = E-coat Al/Cu - E-coat Al/Cu — Louvered Hail Guard
R = Cu/Cu - Al/Cu — Louvered Hail Guard
S = Cu/Cu - Cu/Cu — Louvered Hail Guard
Coil Options – Novation
®
(Outdoor - Indoor - Hail Guard)
G = Al/Al - Al/Cu
H = Al/Al - Cu/Cu
J = Al/Al - E-coat Al/Cu
K = E-coat Al/Al - Al/Cu
L = E-coat Al/Al - E-coatAl/Cu
T = Al/Al - Al/Cu — Louvered Hail Guard
U = Al/Al - Cu/Cu — Louvered Hail Guard
V = Al/Al - E-coat Al/Cu — Louvered Hail Guard
W = E-coat Al/Al - Al/Cu — Louvered Hail Guard
X = E-coat Al/Al - E-coat Al/Cu — Louvered Hail Guard
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18
5
0
T
C
-
A
0
8
A
®
®
2
2
2
Fig. 1 - - 50TC 08- - 12 Model Number Nomenclature (Example)
Model Number
50TC*A08
50TC*D/E08
50TC*A09
50TC*D/E09
50TC*A12
50TC*D/E12
50TC*D/E14
1
A
5
-
0
A
0
A
0
Electrical Options
A = None
C = Non-Fused Disconnect
D = Thru-The-Base Connections
F = Non-Fused Disconnect and
G = 2-Speed Indoor Fan Controller (VFD)
J = 2 Speed Indoor Fan Controller (VFD)
K = 2-Speed Indoor Fan Controller (VFD)
M = 2-Speed Indoor Fan Controller (VFD)
Service Options
0 = None
1 = Unpowered Convenience Outlet
2 = Powered Convenience Outlet
3 = Hinged Panels
4 = Hinged Panels and
Unpowered Convenience Outlet
5 = Hinged Panels and
Powered Convenience Outlet
Intake / Exhaust Options
A = None
B = Temperature Economizer w/ Barometric Relief
F = Enthalpy Economizer w/ Barometric Relief
K = 2-Position Damper
U = Temperature Ultra Low Leak Economizer
w/ Barometric Relief
W = Enthalpy Ultra Low Leak Economizer
w/ Barometric Relief
Base Unit Controls
0 = Electromechanical Controls can be used with W7212
EconoMi$er
1 = PremierLink™ Controller
2 = RTU Open Multi-Protocol Controller
6 = Electro-mechanical w/ 2-Speed Fan and W7220
Economizer Controller Controls. Can be used with
W7220 EconoMi$er X (w/ Fault Detection and Diagnostic)
D = ComfortLink Controls
Design Revision
- = Factory Design Revision
Voltage
1 = 575/3/60
5 = 208-230/3/60
6 = 460/3/60
3
Full Load Airflow (cfm)
2400
2250
3000
3400
3600
3000
3600
Packaging and Seismic Complience
0 = Standard
1 = LTL
3 = California Seismic Compliant Label
4 = LTL and CA Seismic Compliant Label
Thru-The-Base Connections
and Non-Fused Disconnect
and Thru-The-Base Connections
with Non-Fused Disconnect and
Thru-The-Base Connections
®
IV (Non-Fault Detection and Diagnostic)
C150007

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents