Siemens RUGGEDCOM RM1224 Operating Instructions Manual page 13

Industrial remote communication remote networks
Table of Contents

Advertisement

The SET button has the following functions:
Hold down the button for longer than 3 seconds to run a restart.
If the normal procedure with the "Load & Save" menu of Web Based Management does
not work, the reset button can be used to load new firmware. This situation can occur if
there is a power outage during the normal firmware update.
– Hold down the button until the red fault LED (F) starts to flash after approximately 3
– Now release the button. The bootloader waits in this state for a new firmware file that
You will find more information in the section "Service and Maintenance" in the
RUGGEDCOM RM1224 Web Based Management configuration manual.
– Hold down the button until the red fault LED (F) stops flashing after approximately 10
– Now release the button and wait until the fault LED (F) goes off again. The device then
You will find more information in the section "Service and Maintenance" in the
RUGGEDCOM RM1224 Web Based Management configuration manual.
EXPLOSION HAZARD
Do not press the SET button when there is an explosive atmosphere.
RUGGEDCOM RM1224
Operating Instructions, 10/2016, RC1260-EN-02
Restart
Loading new firmware
seconds.
you can download using TFTP.
Reset to factory defaults
seconds and is permanently lit.
starts automatically with the factory settings and can be reached via the IP address
192.168.1.1.
WARNING
Description of the device
1.4 SET button