LIGHT SWITCHES

Door
Switch
1.
See Page 4-14 for access and removal pro-
cedures for the light switches.
2.
Touch the leads of an ohmmeter to the termi-
nals of the normally closed door switch.
3.
The meter should indicate continuity (closed
circuit).
4.
Push the door switch in and the meter should
indicate no continuity (open circuit).
5.
Touch the leads of an ohmmeter to the termi-
nals of the manual rocker light switch.
6.
When the switch is pressed on the "O" side
the meter should indicate no continuity (open
circuit).
7.
When the switch is pressed on the "I" side
the meter should indicate continuity (closed
circuit).
Electrical Shock Hazard
Rocker Light
1.
Switch
2.
3.
5-2
RELAY / OVERLOAD
See Page 4-18 for access and removal pro-
cedures for the Relay / Overload.
Touch one lead of an ohmmeter to the top
terminal on the front and the other lead to the
top terminal on the back of the overload.
The meter should indicate continuity (closed
circuit).
Top terminal on
the front.
Top terminal on
the back.