WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
1.
Remove the evaporator cover. (See page
4-4)
2.
Remove the evaporator fan and motor. (See
page 4-5)
3.
Remove the main thermostat. (See pages
4-6 & 4-7 or 4-8)
4.
Remove the defrost heater and cover. (See
page 4-10)
5.
Remove the defrost thermostat & thermal
fuse. (See page 4-11)
REmOVE THE EVAPORATOR
6.
Remove the evaporator by removing the two
screws that secure the evaporator to the
back wall of the unit. (Photo show screws
already removed so the brackets could be
seen better.)
Evaporator Screws
7.
Access the sealed system and discharge the
refrigerant into an approved recovery sys-
tem.
8.
Unbraze the suction and discharge lines and
remove the evaporator from the unit.
4-12