SUCTION PRESSURE LOW CHECKLIST

Improper Installation
Refer to "Installation/Visual Inspection Checklist"
(page 108)
Discharge Pressure
Discharge pressure is too low and is affecting low
side – refer to "Freeze Cycle Discharge Pressure
High Checklist" (page 113)
Improper Refrigerant Charge
Undercharged
Wrong type of refrigerant
Other
Non-Manitowoc components in system
Improper water supply over evaporator – refer to
"Water System Checklist" (page 109)
Restricted/plugged liquid line drier
Restricted/plugged tubing in suction side of
refrigeration system
TXV starving - continue the table