  • Page 2 HOMEDICS BLOOD PRESSURE MONITOR Before use Before the blood pressure monitor is taken into use, a number of basic steps should be observed. Please read this manual thoroughly before the blood pressure monitor is used for the first time and keep the manual for future use.
  • Page 3 systolic diastolic What are systolic pressure and diastolic blood entering pressure? blood discharging vein artery When ventricles contract and pump blood out of the heart, blood pressure reaches its maximum value, the highest press relax pressure in the cycle is known as systolic pressure. When the heart relaxes between heartbeats, the lowest blood pressure is diastolic pressure.
  • Page 4: Safety Information

    SAFETY INFORMATION Caution: consult accompanying Type B applied part documents Disposal: do not dispose of this product CE mark: conforms to essential as unsorted municipal waste. Collection requirements of the Medical Device of such waste separately for special Directive 93/42/EEC. treatment is necessary.
  • Page 5 LCD display signal Symbol Description Explanation Systolic blood pressure High pressure result Diastolic blood pressure Low pressure result Pulse Pulse/minute Deflating CUFF is deflating Time (hour:minute) Current time The displayed measurement values is from the Memory memory. Measurement Unit of the blood pressure mmHg Measurement Unit of the blood pressure mmHg...
  • Page 6: Monitor Components

    • The display does not light up AC adaptor Alternatively an AC adaptor powered mode CAUTION is available: 100-240V~, 50-60HZ, 400mA (You can purchase the AC adaptor Remove batteries if the device is not likely to be used for PP-ADPR2K3K-EU from the HoMedics some time. website).
  • Page 7 This product uses the Oscillometric Measuring method to detect blood pressure. Before every measurement, the unit establishes a “zero pressure” equivalent to the air pressure. Then it starts inflating the arm cuff, meanwhile, the unit detects pressure oscillations generated by beat-to-beat pulsatile, which is used to determine the systolic and diastolic pressure, and also pulse rate.
  • Page 8: Fitting The Cuff

    22-32cm arm cuff. A large size cuff 32-42cm is available from the HoMedics website www.homedics.co.uk 1. if the cuff is not assembled at first use, put the end of the cuff which is furthest away from the tube through the d-ring to form a noose.
  • Page 9 Worth knowing about blood pressure measurement • Blood pressure measurements should be performed in quiet and comfortable surroundings as measurements can be affected by high or low temperatures. the blood pressure should be measured at normal body temperatures. • do not move or speak during measurement. Keep your feet flat on the floor. •...
  • Page 10 Recalling records 1. Please press the “MEM” to show the recent record. 2. Press the “MEM” or “SET” to get the record you want. DOWN The number of the record, date and time will be shown accordingly. The current record is The month and day The corresponding time shown...
  • Page 11 Error search this section includes a list of error messages and frequently asked questions for problems you may encounter with your blood pressure monitor. if irregularities occur during use, please check the following items. PROBLEM SYMPTOM CHECK THIS REMEDY Batteries are exhausted. Replace with new batteries Display is dim or will No power...
  • Page 12: Specifications

    Specifications Battery powered mode: 6VDC 4*AA batteries AC adaptor powered mode: 100-240V~, 50-60HZ, 400mA Power supply (You can purchase the AC adaptor PP-ADPR2K3K-EU from the HoMedics website). Display mode Digital LCD V.A.93*61mm Measurement mode Oscillographic testing mode Pressure: 0~40kpa (0~300mmHg)
  • Page 13: Cleaning And Maintenance

    Cleaning and maintenance the blood pressure monitor and the cuff can be wiped with a soft cloth moistened with a mild detergent and wiped dry with a soft, dry cloth or paper towel. never use strong, caustic detergents as these may cause damage to the synthetic parts.
  • Page 14 SYSTEMS Guidance and manufacture’s declaration – electromagnetic emission The BPA-2000-EU is intended for use in the electromagnetic environment specified below. The customer of the user of the BPA-2000-EU should assure that it is used in such and environment. Emission test Compliance Electromagnetic environment –...
  • Page 15 ME EQUIPMENT and ME SYSTEMS Guidance and manufacture’s declaration – electromagnetic immunity The BPA-2000-EU is intended for use in the electromagnetic environment specified below. The customer or the user of BPA-2000-EU should assure that it is used in such an environment.
  • Page 16 Table 3 Guidance and manufacture’s declaration – electromagnetic immunity – for ME EQUIPMENT and ME SYSTEMS that are not LIFE-SUPPORTING NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
  • Page 17 Recommended separation distances between portable and mobile RF communications equipment and the ELE007839V1 Fitness Equipment. The BPA-2000-EU is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the BPA-2000-EU can help prevent electromagnetic interference...
  • Page 18 Register your product today at: http://www.homedicsgroup.com/register IB-BPA-2000EU-0912-01...

This manual is also suitable for:

Bpa-3000-eu

Table of Contents