Enduro Ice/Beverage Dispenser Operator's Manual

PORTION CONTROL PANEL OPERATIONS

Light Color
Green
Green --
flashing
Red then
Yellow
ICE PORTION CONTROL SETUP AND ADJUSTMENT PROCEDURE
Light Color
Step 1. Fill the Ice
Yellow Flashing
Chute
620916502OPR
Explanation
Normal Operation
Normal Operation Chute Refil-
ling
Clean Mode
Explanation
Chute Agitation Refill Time
4
Actions That Can Be Taken
Press andy CUP SIZE for portioned
ice.
--or--
Press INCREASE and then CUP
SIZE for extra ice.
Wait until chute has refilled and press
desired CUP SIZE again.
To enter Clean Mode simultaneously
press INCREASE and DECREASE.
Press any CUP SIZE to empty chute,
then remove chute for cleaning.
When chute is replaced, unit automat-
ically returns to normal operation after
one minute, or INCREASE and DE-
CREASE can simultaneously pressed
3 times.
Actions That Can Be Taken
To enter Agitation Adjustment Mode
simultaneously press INCREASE
and DECREASE three times then
press and hold INCREASE and DE-
CREASE for 3 seconds.
Press any CUP SIZE to select a
preset agitation time (small=short-
est time, X--Large=longest time,
ect)
To exit Agitation Refill Time Adjust-
ment Mode simultaneously press
INCREASE and DECREASE.
NOTE: Once in a mode the light
blinks to indicate the refill time: 1
blink for the shortest refill time and
4 blinks for the longest refill. The
factory recommendation is 2 blinks.
NOTE: Larger ice portions require
more time to refill.