Horcm_Ldevg - Hitachi VSP F1500 User And Reference Manual

Command control interface guide
Hide thumbs Also See for VSP F1500:
Table of Contents

Advertisement

logical volume names described in this item must also be known to the
remote server.
dev_group: This parameter is the same as HORCM_DEV parameter.
dev_name: This parameter is the same as HORCM_DEV parameter.
MU#: This parameter is the same as HORCM_DEV parameter.
Serial#: This parameter is used to specify the serial number of RAID box.
For VSP G1000, G1500, and VSP F1500, add a "3" at the beginning of the
serial number. For example, for serial number 12345, enter 312345.
CU:LDEV(LDEV#): This parameter is used to describe the LDEV number in
the RAID storage system and supports three types of format as LDEV#.
#dev_group
¢
¢
¢

HORCM_LDEVG

The HORCM_LDEVG parameter defines the device group information that the
CCI instance reads. For details about device group, see
function on page
The following values are defined.
Copy group: specifies a name of copy group. This is equivalent to the
dev_group of HORCM_DEV and HORCM_LDEV parameters.
CCI operates by using the information defined here.
ldev_group: Specifies a name of device group that the CCI instance
reads.
Serial#: Specifies a storage system serial number. For VSP G1000,
G1500, and VSP F1500, add a "3" at the beginning of the serial number.
For example, for serial number 12345, enter 312345.
dev_name
oradb
dev1
oradb
dev2
Specifying "CU:LDEV" in hex.
Example for LDEV# 260:
01:04
Specifying "LDEV" in decimal used by the CCI inqraid command.
Example for LDEV# 260:
260
Specifying "LDEV" in hex used by the CCI inqraid command.
Example for LDEV# 260:
0x104
Note: The HORCM_LDEV format can only be used on the TagmaStore
USP/TagmaStore NSC. LDEV# will be converted to "Port#, Targ#,
Lun#" mapping to this LDEV internally, because the RAID storage
system needs to specify "Port#, Targ#, Lun#" for the target device.
This feature is TagmaStore USP/TagmaStore NSC microcode
dependent; if HORCM fails to start, HORCM_DEV needs to be used.
3-35.
CCI software environment
Command Control Interface User and Reference Guide
Serial#
CU:LDEV(LDEV#)
30095
02:40
30095
02:41
MU#
0
0
LDEV grouping
2-27