Horcm_Dev - Hitachi VSP F1500 User And Reference Manual

Command control interface guide
Hide thumbs Also See for VSP F1500:
Table of Contents

Advertisement

HORCM_CMD
#dev_name dev_name dev_name
\\.\CMD-64015:/dev/rdsk/*
The following expresses the case when both the in-band and out-band
methods are used in a command device alternative configuration:
HORCM_CMD
#dev_name dev_name
\\.\CMD-64015:/dev/rdsk/*
HORCM_CMD
#dev_name dev_name
\\.\IPCMD-158.214.135.113-31001
The following expresses the case of virtual command devices in a cascade
configuration (three units):
HORCM_CMD
#dev_name dev_name dev_name
\\.\IPCMD-158.214.135.113-31001
\\.\IPCMD-158.214.135.114-31001
\\.\IPCMD-158.214.135.115-31001
The following example shows the case of alternative configuration of the
combination of all GUM IP addresses in the storage system and the UDP
communication port numbers. In this case, enter the IP address without a
line feed.
HORCM_CMD
#dev_name dev_name dev_name
\\.\IPCMD-192.168.0.16-31001
\\.\IPCMD-192.168.0.17-31001
\\.\IPCMD-192.168.0.16-31002
\\.\IPCMD-192.168.0.17-31002
An IP address and a port number can be expressed using a host name and a
service name.

HORCM_DEV

The device parameter (HORCM_DEV) defines the RAID storage system device
addresses for the paired logical volume names. When the server is connected
to two or more storage systems, the unit ID is expressed by port# extension.
Each group name is a unique name discriminated by a server that uses the
volumes, the attributes of the volumes (such as database data, redo log file,
UNIX file), recovery level, etc. The group and paired logical volume names
described in this item must reside in the remote server. The hardware iSCSI/
Fibre port, target ID, and LUN as hardware components need not be the
same.
The following values are defined in the HORCM_DEV parameter:
dev_group: Names a group of paired logical volumes. A command is
executed for all corresponding volumes according to this group name.
dev_name: Names the paired logical volume within a group (that is,
name of the special file or unique logical volume). The name of paired
logical volume must be different to the dev name in another group.
Port#: Defines the RAID storage system port number of the volume that
connects to the dev_name volume. The following "n" shows unit ID when
CCI software environment
Command Control Interface User and Reference Guide
\\.\IPCMD-158.214.135.113-31001
\\.\IPCMD-158.214.135.113-31001
\\.\CMD-64015:/dev/rdsk/*
2-23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents