3. Wiring the Power Inputs
The 6-contact terminal block connector on the top panel of Managed Industrial
Switch is used for two DC redundant powers input. Please follow the steps below
to insert the power wire.
1. Insert positive / negative DC power wires into the contacts 1 and 2 for POWER
2, or 5 and 6 for POWER 1.
2. Tighten the wire-clamp screws for preventing the wires from loosing.
The wire gauge for the terminal block should be in the range
between 12 ~ 24 AWG.