Bridge Profile Configuration Examples - Lucent Technologies MAX 6000 Network Configuration Manual

Hide thumbs Also See for MAX 6000:
Table of Contents

Advertisement

2
Table 14-2.Ascend-Bridge-Address arguments
Argument
MAC_address
profile_name
IP_address
Each Ascend-Bridge-Address setting specifies the IP address and associated MAC address of a
device on a remote LAN to which the MAX can form a bridging connection. When your MAX
receives an ARP request for one of the IP addresses you specify, the MAX replies with the
corresponding MAC address and uses the specified profile to bring up a connection to that
address. Because the MAX replies to these ARP requests as if the IP devices were local, you
must have user profiles that bridge IP packets to each device.
Whenever you power on or reset the MAX, or when you select the Upd Rem Cfg command
from the Sys Diag menu, RADIUS adds bridging entries to the bridge table in this way:
1
2

Bridge profile configuration examples

The following profile specifies two bridging table entries.
Bridge-Ascend-1 Password="Ascend", User-Service=Dialout-Framed-User
Ascend-Bridge-Address="2:2:3:10:11:12 Prof1 1.2.3.4 1",
Ascend-Bridge-Address="2:2:3:13:14:15 Prof2 5.6.7.8 2"
MAX 6000/3000 Network Configuration Guide
-
Bridge-unit_name
num Password="Ascend", User-Service=
Dialout-Framed-User
unit_name is the system name of the MAX—that is, the name specified by the Name
parameter in the System profile. num is a number in a sequential series, starting at 1.
For each pseudo-user profile, specify one or more bridge entries using the
Ascend-Bridge-Address attribute.
The Ascend-Bridge-Address attribute has this format:
Ascend-Bridge-Address="MAC_address profile_name IP_address"
Table 14-2 describes Ascend-Bridge-Address arguments.
Description
Specifies a MAC address in standard 12-digit hexadecimal
format (yyyyyyyyyyyy) or in colon-separated format
(yy:yy:yy:yy:yy:yy). If the leading digit of a colon-separated
pair is 0 (zero), you do not need to enter it. That is,
same as
The default value is 000000000000.
Specifies the name of the dialout profile the MAX uses to bring
up the connection. You can specify either a Connection profile
or a RADIUS user profile. The MAX looks for a local profile
first.
Specifies an IP address in dotted decimal notation. The default
value is 0.0.0.0.
RADIUS looks for profiles having the format Bridge-
is the system name and
unit_name
1.
RADIUS loads the data to create the bridging tables.
Configuring Packet Bridging
Configuring bridged connections
.
:0y
unit_name
is a number in a sequential series, starting with
num
is the
:y
-
, where
num
14-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Max 3000

Table of Contents