Technical Specifications
Section 4.2

Failsafe Relay Specifications

Rated Switching Current
Maximum Switching Capacity
Section 4.3
Supported Networking Standards
Section 4.4
Copper Ethernet Port Specifications
The following details the specifications for copper Ethernet ports that can be ordered with the RUGGEDCOM
RSG2288.
NOTE
• Maximum segment length is greatly dependent on factors such as fiber quality, and the number
of patches and splices. Consult a Siemens sales associate when determining maximum segment
distances.
• All optical power numbers are listed as dBm averages.
• F51 transceivers are rated for -40 to 85 °C (-40 to 185 °F).
Connector
Speed
e
Duplex
30
Parameter
Max Switching Voltage
Standard
IEEE 802.3
IEEE 802.3u
IEEE 802.3z
IEEE 802.3ab
IEEE 802.3x
IEEE 802.1D
IEEE 802.1Q
IEEE 802.1p
IEEE 1588 v2
RJ45
1000 Mbps
FDX/HDX
Value (Resistive Load)
240 VAC, 125 VDC
2 A @ 240 VAC, 0.15 A @ 125 VDC, 2 A @ 30 VDC
150 W, 500 VA
Description
10BaseT
100BaseTX/100BaseFX
1000BaseSX/LX
1000BaseTx
Flow Control
MAC Bridges
VLAN (Virtual LAN) Tagging
Class of Service
Precision Time Protocol
Failsafe Relay Specifications
RUGGEDCOM RSG2288
Installation Guide