cessively high current can lead
to a cable fire or damage to the
vehicle electronics.
Do not use the socket to
jump-start the engine of the
motorcycle.
A short-circuit can result
if the crocodile clips of
the jump leads are accidentally
brought into contact with the
motorcycle.
Use only jump leads fitted with
fully insulated crocodile clips at
both ends.
Jump-starting with a donor-
battery voltage higher than
12 V can damage the motorcycle
electronics.
The battery of the donor vehicle
must have a voltage of 12 V.
Park motorcycle, ensuring that
support surface is firm and
level.
Remove battery cover (
Do not disconnect the battery
from the onboard electrical sys-
tem when jump-starting the
engine.
Remove the protective cap 1.
Begin by connecting one end
of the red jumper cable to the
positive terminal 2 on the dis-
charged battery and the other
end to the positive terminal of
the donor battery.
If the 12 V battery is in-
stalled incorrectly, or if the
terminals are interchanged (dur-
141).
ing jump-starting, etc.), the fuse
for the voltage regulator may
burn through.
Connect black jumper cable
to negative terminal on donor
battery and then to negative
terminal 3 of discharged bat-
tery.
Run engine of donor vehicle
during jump-starting procedure.
Start engine of vehicle with dis-
charged battery in usual way;
if engine does not start, wait
a few minutes before repeat-
ing attempt in order to protect
starter motor and donor bat-
tery.
Allow both engines to idle for a
few minutes before disconnect-
ing jumper cables.
Disconnect jumper lead from
negative terminal first, then
from positive terminal.