Installation (for qualified installers only)

Optional Wall Switch or Thermostat Installation

Do not connect 110-120 VAC to the gas control valve or wiring system of this stove. The switch must be
installed by a qualified installer.
Caution:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper operation after servicing.
Note:
When using a GreenSmart™ remote, use the receiver for on/off operation (do not use a wall
switch or thermostat).
Warning:
Make sure all wiring is secure and does not contact hot or moving components.
The wall switch (or thermostat) may bypass the fireplace on/off switch or be installed in parallel or series
configuration (see below).
Parallel Connection
Thermostat / External
Switch ON
Thermostat / External
Switch OFF
To wire the heater in parallel, follow the directions below:
a
On / Off Switch
c
© Travis Industries
On / Off Switch
On / Off Switch
ON
OFF
Heater is ON
Heater is ON
Heater is ON
Heater is OFF
b
Thermostat
(or External Switch) Wires
10/2/17 - 1454
Series Connection
On / Off Switch
Thermostat /
Heater is ON
External Switch ON
Thermostat /
Heater is OFF
External Switch OFF
To wire the heater in series, follow the directions below:
a
On / Off Switch
c
On / Off Switch
ON
OFF
Heater is OFF
Heater is OFF
b
Thermostat
(or External Switch) Wires
Berkshire MV