Programming [Ezsq: Easy Sequence] Function; Emc Filter & Brake Circuit Integrated As Standard - Hitachi SJ700 series Manual

Powerful inverter with sensorless vector control
Hide thumbs Also See for SJ700 series:
Table of Contents

Advertisement

High performance, powerful functions,
yet user friendly.

Programming [EzSQ: easy sequence] function

Inverter control by built-in
programming functions
Custom operation is realized by downloading to an inverter a
user program created with ProDriveNext, Hitachi inverter
configuration software.
Tailor inverter operation to meet changing process
requirements, and replace separate PLCs in some cases.
By simplifying or eliminating external hardware, signficant cost
savings can be achieved.
Password function is incorporated to provide security for proprietary
program data against loss or unauthorized modification.
Typical example - Replacing external relay circuit
Standard Inverter
PB2
PB1
RY1
T2
RYA
RY1
T1
PB1
PB2
RY2
T1
RYB
RY2
Operation
T2
circuit
RYA
FW
RYB
8
CM1
EMC Filter & brake circuit integrated as standard
Built-in EMC filter up to 150kW
Cost and space reduction compared with external EMC filter.
Reduces electromagnetic noise.
SJ700: European Version and Japanese Version does not have 150 kW
*
SJ700B: All models(5.5kW is without EMC Filter)
Built-in brake resistor
circuit up to 22kW
Cost and space reduction compared with external braking controller.
SJ700B: Up to 30kW
*
SJ700 Using EzSQ
EzSQ
Programming
Programming Window
Download
PB1
1
PB2
2
CM1
Meets EN61800-3 2nd-Environment
*
Item
Language type
BASIC Like
Supported Device
Windows (DOS/V)OS:WindowsVista, Windows7)
1,024 steps or 6k byte
Memory area
(Smaller of these)Program is stored in internal of inverter.
Editor (Windows), Display (Windows)
Programming
Syntax check (Windows)
environment
Program download/upload, All clear
Executable format
Interpreter 2.0ms/command (Sub routine supported. 8 nested)
Contact signal/Open collector signal input
(Internal DC24V power supply available)
External digital
Program RUN
contact input
command
General-purpose
External input
input
XA (0) : 0-10V (O terminal)
External analog
XA (1) : 4-20mA (OI terminal)
input
XA (2) : 0-10V (O2 terminal)
General-purpose
Maximum of 6 point (Y (00)-Y (05))
output terminal
YA (0) : Setup for FM terminal is possible.
External output
External analog
YA (1) : Setup for AM terminal is possible.
output
YA (2) : Setup for AMI terminal is possible.
Programmable flow control <Loop, Unconditional jump, conditional jump,
Time control, Sub routine, Others>
Operation command <+,-,,*, /, substitution, mod, abs>
Command
I/O control (Bit input, Word input, Bit output, Word output)
Timer control <on delay, off delay>
Inverter parameter setting
User
U (00)-U (31)/32 point
Timer
UL (00)-UL (07)/8 point
Set frequency
SET-Freq
Acceleration time
ACCEL
Deceleration time
DECEL
Output frequency, Output current, Rotation direction,
PID feedback, Converted frequency, Output torque,
Monitor
Output voltage, Power, Cumulative RUN time,
Cumulative power-on time, trip
Variable
General-purpose
X (00)-X (07)/8 point
input contact
General-purpose
Y (00)-Y (05)/6 point (1 point is relay output)
output contact
Internal user
UB (00)-UB (07)/8 point
Internal timer
TD (0)-TD (7)/8 point
contact
Inverter input
In a remote operator display code.
and output
®
*
Windows
is a registered trademark of Microsoft Corporation.U.S.A and other countries.
*
Example (SJ700D-110HFEF3)
130
120
110
100
90
80
70
60
50
40
30
20
10
0
150k 200k
500k
Description
SJ700D:PRG terminal
SJ700/SJ700B:FW terminal
Maximum of 8 point (X(00)-X (07))
EN61800-3 2nd Environment
[C3]QP Limit Level
1M
2M
5M 7M 10M
20M 30M
Frequency [Hz]
QP: Quasi Peak
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sj700b series

Table of Contents