14 Troubleshooting - BEA IS40 User Manual

Combined active infrared (ir) and microwave sensor
Hide thumbs Also See for IS40:
Table of Contents

Advertisement

REMOTE CONTROL PARAMETERS (CONTINUED)
12
QUESTION A VALUE
13
SENSOR SETUP SEQUENCE / FACTORY VALUES / ACCESS CODE
IMPORTANT: ENSURE TO SAVE ANY
CHANGES DURING THE ADJUSTMENT
SESSION VIA PRESSING LOCK LOCK.
IMPORTANT: ALWAYS FINISH AN ADJUSTMENT
SESSION BY LAUNCHING A SETUP.
RESETTING TO FACTORY VALUES
SETTING AN ACCESS CODE
DELETING AN ACCESS CODE
If you do not know the access code, cycle the power supply.
Within 1 minute, you can access the sensor without introducing any access code or delete the existing access code per the instrucitons above.
14
TROUBLESHOOTING
SYMPTOMS
The door never closes and the
red LED is on.
The red LED is on during rain or
snow.
The red LED is permanently on
after a setup.
The door keeps recycling open
or closed.
The door never closed and the
LED(s) is off.
Page 8 of 9
Check parameter values
POSSIBLE CAUSES
Objects in the IR detection area.
The presence detection is disturbed
by the rain or snow.
Setup has failed due to motion in the
IR field during setup.
The sensor detects door movement.
The sensor detects door vibrations
or environmental disturbances.
Output relay(s) could be wired or
configured backwards.
x
The number of green flashes
indicates the value of the
chosen parameter.
New
Parameter
Value
CORRECTIVE ACTION
Move objects or reduce automatic learn
time.
Wait for learn time to expire and/or
Launch a setup.
Increase the immunity of the IR field.
(value 2 or 3 respectively).
Launch a setup with the IR area clear of
moving objects.
Change the sensor angle and/or
microwave field angle.
Increase microwave rejection and/or IR
immunity. Secure mounting bracket.
Change wiring at output(s) and/or
change relay configuration.
75.5695.01 EN 20120113