Fig. 25
6.
Remove all pipe fittings from old valve if new
valve is not supplied with fittings.
7.
Reverse procedure to install.

FRY TANK

Oil may be hot when draining fryer tank.
Shut off the gas before servicing the
unit and follow lockout / tagout
procedures.
1.
Disconnect fryer from main gas line.
2.
Remove all baskets, fryer basket hanger and
crumb screen.
LG Series Fryer - REMOVAL AND REPLACEMENT OF PARTS
3.
DRAIN FRYER TANK .
4.
Remove HEAT SHIELD.
5.
Remove FLUE WRAP.
6.
Remove FLUE BOX.
7.
Remove BACK PANEL.
8.
Remove BURNERS and manifold bracket (Fig.
26).
9.
Remove THERMOSTAT.
10. Remove HIGH LIMIT THERMOSTAT.
11. Remove pilot assembly bracket.
12. Lift tank up and out of cabinet.
13. Remove drain valve from tank.
14. Reverse procedure to install.
Page 11 of 23
Fig. 26
Fig. 27
F45691 (1117)