Adjustment
(5) DC-DC Pack Voltage Set up Range
Vsetup : 210V ~ 240V
Vsc : 90V ~ 120V
-Vy : -60V ~ -80V
-Ve : -35V ~ -45V
(1) The power of the signal generator should be turned on before turning on the power of DC power
supply.
(2) The voltage of DC power supply , in standard of Module input voltage, should be preset as
below.
Vcc: 5V, Va: 65V, Vs: 190V
(3) The power of power supply must turned on by this sequence. Reverse direction When turning
off.
* Module on : 5V
(4) Signal generator should be selected with 852*480 mode(WVGA)
<Caution>
Va
Vs, Module off: Vs
-51-
Va
5V