SERVICE MODE
(2) BWINV : Used to minimize Image Sticking
(ON/OFF)
ON : Inverting the original images.(in Digital image
data, 0
* If Still images have been displayed for some
periods, this function can minimize Image sticking,
by displaying it on BWINV mode for some times.
(3) GAMMA : can choose one in 4 gamma tables
(4) BRIGHT : Adjusting Peak Luminance
1. 100% : Full Peak Luminance
2. 63% : 63% of Peak luminance
3. 40% : 40% of Peak luminance
(* See the graph below)
4. APL: Average Picture Level
(5) SCROLL : Minimizing Image Sticking (ON/OFF) by Shifting whole screen BRIGHT :
Adjusting Peak Luminance. (same with PXL SFT function in 6.MISC)
(6) BRIGHT : Adjusting Peak Luminance
(7) P SAVE : Controlling power consumption by changing Luminance level of whole screen.
1. 100% : Peak Luminance & Maximum Power Consumption mode
2. 87% : 87% mode
3. 75% : 75% mode
4. 50% : 50% mode
5. linear : linear mode(Constant luminance without regard to APL)
* WARNING!! The choice of these modes can cause difference of Power Consumption.
* See the below
(8) MOVING : Setting display mode of Input channel except PC input.
(9) STILL : Setting display mode for PC input.
1 , 1
0 )
ON : This function moves1~8 pixel with a regular rule, up, down, left, right every
10 sec
Table
1
2
3
4
-22-
Gamma Contents
=2.2
=1
=2.1 (default)
=2.4

Advertisement