Figure 26: Gas Connection With Stainless Steel Flex Gas Connector - Roberts Gorden CoRayVac CRT-10 Installation, Operation & Service Manual

Custom-engineered, low-intensity infrared heating systems
Hide thumbs Also See for CoRayVac CRT-10:
Table of Contents

Advertisement

Figure 26: Gas Connection with Stainless Steel Flex Gas Connector

Shut-Off Valve must be parallel to
burner gas inlet. The 80 mm
displacement shown is for the cold
condition. This displacement may
reduce when the system is fired.
Shut-Off Valve
300 mm
Stainless
Steel Flex
Gas Connector
Heater Movement
Heater Movement
Description
1/2" Flex Gas Line
Shut Off Valve
CORRECT POSITIONS
80 mm
Burner
INCORRECT POSITIONS (WRONG INSTALLATION)
Part Number
E0009397
C0514B
CAUTION
Product Damage Hazard
Hold gas nipple securely with pipe wrench
when attaching gas hose.
Failure to follow these instructions can result
in product damage.
Horizontal
Heater Movement
Heater Movement
SECTION 10: G
P
AS
IPING
45°
Rear View
37 of 54