Quadra-Fire MTVI-E2-MBK-C Manual page 25

Mt. vernon e2 insert pellet appliance
Hide thumbs Also See for MTVI-E2-MBK-C:
Table of Contents

Advertisement

Following correction of any Alarm, turn the dial control to the OFF position, wait 10 seconds and turn back to
desired setting OR unplug the appliance, wait 10 seconds then restore power.
Alarm
(LED Flashing RED)
1 Red Flash: Empty Hopper Alarm
2 Red Flashes: Exhaust Probe Fail
4 Red Flashes: Missed Ignition
6 Red Flashes: Exhaust Blower
Alarm
8 Red Flashes: Exhaust Over-Temp
November 28, 2017
Possible Cause
Hopper empty
Auger jam
Vacuum switch not closing
Hopper lid open
Exhaust probe does not sense tem-
perature
Snap disc tripped (#3)
Exhaust probe not attached to
exhaust blower properly
Exhaust path is dirty
Not connected to the control board
Failed component
Hopper empty
Feed motor doesn't turn
Dirty appliance
Igniter has no power or is defective
Exhaust probe not properly installed
Igniter chamber plugged with debris
Wire from exhaust blower or encoder
is disconnected or shorted
Defective exhaust blower
Defective encoder (on end of
exhaust blower)
Feed Motor Locked On
Non-approved fuel used
Convection blower dirty
7082-151C
MT. VERNON E2 INSERT-C
Corrective Action
Fill the hopper
Inspect the feed tube for jams
Make sure firebox door is shut,
vacuum hose is connected to switch
and drop tube, wire connectors are
connected to vacuum switch, control
board, hopper switch, and safety
snap disc.
Close the hopper lid
Secure the exhaust probe keeping
its wire away from hot surfaces and
clean the exhaust plenum
Reset snap disc
Secure exhaust probe to exhaust
blower housing – keeping its wire
away from hot surfaces
Clean appliance including the fire pot,
exhaust path, and venting system
Connect terminal end to control board
Replace exhaust probe – securing it
to exhaust blower housing – keeping
wire away from hot surfaces
Fill the hopper
Inspect feed motor circuit (hopper lid
must be closed, vacuum switch must
be closed, snap disc closed, and feed
motor must be plugged in)
Clear jam in feed tube
Clean appliance including the fire pot,
exhaust path, and venting system
Check igniter lead connections or
replace igniter
Secure exhaust probe to exhaust
blower housing – keeping its wire
away from hot surfaces
Clean igniter chamber
Make sure wire is not damaged /
melted and ends are fully connected
to the encoder and control board.
Replace exhaust blower
Replace exhaust blower
Repair wire(s) and replace control
board
Only use wood pellet fuel. Do not
enhance its performance with any
other combustible substance.
Clean impellers
25