Auto Force Adjustment

To prevent SERIOUS INJURY or DEATH from improper Force Adjustment:
- DO NOT adjust force to compensate binding or sticking of the garage door. Call a qualified garage door
service person to make necessary adjustments in case of binding.
- DO NOT increase force beyond minimum force required for closing the door. Too much force will cause
improper operation of safety reversal mechanism.
- After ANY adjustments, Safety Reverse Test MUST be performed to ensure the door reverses on contact
with a 1.5" high object (2x4 laid flat).
Auto Force Adjustment
1
FORCE
UP
LIMIT
DOWN
2
I
Travels up
III
Travels down
3
OK
!
UP
x1
DOWN
II
2s
Stops at UP limit for
2 seconds
IV
Stops at DOWN limit
Flashes
x2
WARNING
Following
limit-setting,
automatically adjust the forces for opening and closing the
door. Proceed with the following steps to complete
adjustment.
1.
With both "UP" and "DOWN" indicators are on after Travel
Limit Adjustment, press the "FORCE" button once to enter
Auto Force Adjustment.
2.
The door will travel up automatically (I) and stop at UP
limit for 2 seconds (II). Door will then travel down
automatically (III) and stop at down limit (IV).
3.
The "OK" indicator (orange) will flash with beeps, the Auto
Force Adjustment is completed.
the
unit
is
now
ready
to
19