5 Performance Data / Operation
Limitation by the CPU
In productive operation, the number of simultaneous SEND/RECEIVE calls
depends on the CPU resources being used. Note the information on the available
CPU resources in Section 2.2.
The following CPU resources are required:
S Per SEND job short (FC5) or long (FC50):
S Per RECEIVE job short (FC6):
S Per RECEIVE job long (FC60):
S Per SPEED SEND/RECV job (FC53, FC63):
Limitation by the CP
A maximum of 64 SEND/RECEIVE connections can be operated by the CP.
At an assignment of 1 CP per CPU, the maximum number of SEND/RECEIVE
calls that can be used at one time is limited as follows:
S SEND calls short (FC5) or long (FC50):
S RECEIVE calls short (FC6):
S RECEIVE calls long (FC60):
)
*
The values apply to the CPU 416 and CPU 417.
)
*
The values apply to the CPU 412 and CPU 414.
)
***
The number of FC60s that can be used at the same time depends on the
number of SEND calls active at the same time (see Tables 5-4 and 5-5).
Table 5-4
Dependency of the maximum number of RECEIVE calls long (FC60) used at the same time
on the number of SEND calls (CPU 412/414)
Number of
simultaneous SEND
calls
Max. number of
simultaneous FC60s
per CPU 412/414
B−26
0
1
2
3.
4
19
18
17
16
max. 32*
max. 64*
5
6
7
8
9
15
14
13
12
CP 443-1 for Industrial Ethernet / Manual Part B
1 resource
1 resource
2 resources
0 resources
)
)
/ 12**
per CPU
)
)
/ 24**
per CPU
)
variable ***
10
11
12
11
10
9
Release 07/2010