7-4. Diagnostic Help Codes

Display Code
CbL Err
PoL Err
H1
H2
H3
H4
H5
H8
H12
H13
H14
H15
H23
H24
H25
H40
H42
OM-264234 Page 30
H1
Example Display
Fault
Cable Error
Polarity Error
Input Current Sensor Malfunction
Thermistor Open Or Shorted
Secondary 1 Over−Temperature
Secondary 2 Over−Temperature
Secondary 3 Over−Temperature
Output Over−Voltage
Bus Voltage Low
Voltage Sense
Bus Voltage High
Bus Voltage Low While Welding
No Active Fault
Undefined Fault
Duty Cycle Limit Exceeded
Tach Error On Motor
Motor Error On Motor
Description
Cable arrangement between welding power source
and Smart Feeder is preventing proper operation. Un-
coil the work and welding cables. Lay the cables
straight and close together. Cables that are first laid
out straight and close together may then be coiled
together.
Indicates wrong polarity. Turn Welding Power Source
off. Make sure that work and welding cables are con-
nected properly. (See Sections 5-2 and 5-8 for con-
nection instructions.)
Indicates current sensor is malfunctioning. If this code
appears, contact nearest Factory Authorized Service
Agent.
Indicates thermal protection circuitry is malfunctioning.
If this code appears, contact nearest Factory Autho-
rized Service Agent.
Indicates feeder has overheated. Unit has shut down
to allow fans to lower temperature. Operation will con-
tinue after unit is within normal temperature range.
Indicates feeder has overheated. Unit has shut down
to allow fans to lower temperature. Operation will con-
tinue after unit is within normal temperature range.
Indicates feeder has overheated. Unit has shut down
to allow fans to lower temperature. Operation will con-
tinue after unit is within normal temperature range.
Indicates secondary power circuit malfunction. If this
code appears, contact nearest Factory Authorized
Service Agent.
Indicates Bus capacitor malfunction. If this code ap-
pears, contact nearest Factory Authorized Service
Agent.
Indicates Voltage sense malfunction. If this code ap-
pears, contact nearest Factory Authorized Service
Agent.
Indicates Bus over voltage malfunction. If this code
appears, contact nearest Factory Authorized Service
Agent.
Indicates Bus under voltage malfunction. If this code
appears, contact nearest Factory Authorized Service
Agent.
N/A
N/A
Indicates duty cycle limit has been exceeded. Output
stops and the cooling fan will run. Wait about 15 min
for unit to cool. Reduce Amperage, Voltage, Wire feed
speed, or duty cycle before restarting.
Indicates tach error on motor. Check feeder drive
housing and wire spool for obstructions. If this code
continues to appear on the display, contact nearest
Factory Authorized Service Agent.
Indicates a motor error. Check feeder drive housing
and wire spool for obstructions. If this code continues
to appear on the display, contact nearest Factory Au-
thorized Service Agent.